9
The membrane maximum temperature specification is 120F. This module must be installed in
an area that maintains a temperature below 120F (50C). A cool location is preferable. Make
sure that the area around and under the pump does not have any water sensitive equipment.
Water will be spilled during any repairs or if a leak occurs.
Be sure you will have clearance to open the lid of the enclosure, and leave room to remove all
side and top panels for easy servicing..
The Spectra-Pearson Pump Module comes complete with a mounting system.
Be sure to
mount the Module horizontally
and securely bolt the Spectra-Pearson Pump Module to a shelf
or level surface.
The high pressure pump and membrane assembly has been pre-assembled at the factory. If it
is necessary to disassemble this unit and mount the pressure vessels remotely use the
guidelines on
pg 39
of the manual. Use only approved hoses for assembly.
Spectra-Pearson Pump Module
Membrane Pressure Vessel Mounting
Содержание Farallon 1800
Страница 2: ...2...
Страница 15: ...15 John Guest Super Speedfit Fittings...
Страница 39: ...39 Oil nipple threads and inside of hose with silicone oil or diluted soapy water DO NOT OIL HOSE COVER...
Страница 43: ...43...
Страница 44: ...44 Farallon 1800 Settings Farallon 2800 Settings...
Страница 45: ...45 Float Switch Wiring...
Страница 53: ...53...