22
7
.
The system is now in the operational mode. You may start and run your system as you
desire. You will not have to go through the purging mode unless you shut-off power to the
system. If you do, you can bypass the purging mode by pushing
“Stop”
and
“Auto run”
buttons at the same time. It is best to use the “
Auto-Run”
and “
Auto-Store”
button to
start and stop the machine. If you shut down the system using the “
Stop”
button, then
press the
“auto store”
button to do a fresh water flush cycle.
4. Press Auto Run Button
to start the watermaker
Note:
If you must stop the purge sequence for any reason, the control will default back to
the beginning of the purging mode to protect your system. If you wish
you can
bypass the purge sequence
and initiate a normal start. Pressing both “
Auto Run”
and “
Stop”
simultaneously anytime during the purge sequence will bypass the purge
sequence and enable a normal start. Do not bypass the purge mode unless you are
certain that no storage or cleaning chemicals are present in the system.
Do not
pressurize the system for the first twenty minutes
or more. Make sure that you
have purged the system adequately or you will damage the membrane.
5. After the purge sequence. The control will alarm with the message “Close pressure relief
valve” -
Close the pressure relief valve
and proceed by pressing “
Auto Run.
”
6. The system is now running under pressure and making water. The display will read
“purging product water.”
This mode sends the product water overboard for ten minutes
in case there are any residual chemicals in the membrane. Carefully inspect for leaks over
the entire system! Shut down the system and repair any leaks you find.
8. Check that the system is operating within its normal parameters. Compare with the chart
on the next page. Be sure to remove the paper battery isolating tab on the MPC battery
backup after completing the purge sequence.
The system will go into a start mode and the Spectra-Pearson Pump will start shortly after.
The system should prime within 60-90 seconds. Check the strainer and the brine discharge for
water flow. There should be no bubbles anywhere in the intake hoses and the Spectra-Pearson
Pump should sound smooth after priming. If it continues to sound rough, find the reason
before continuing! Inspect the system for leaks.
If the system continually alarms ‘Service Prefilter’ at the
beginning of the purge sequence, then air may be trapped in
the prefilter housings. Use the ‘Air Purge Button’ on top of
the filter housings to evacuate the trapped air, and try again.
Содержание Farallon 1800
Страница 2: ...2...
Страница 15: ...15 John Guest Super Speedfit Fittings...
Страница 39: ...39 Oil nipple threads and inside of hose with silicone oil or diluted soapy water DO NOT OIL HOSE COVER...
Страница 43: ...43...
Страница 44: ...44 Farallon 1800 Settings Farallon 2800 Settings...
Страница 45: ...45 Float Switch Wiring...
Страница 53: ...53...