16
Wiring
PROVIDE CIRCUIT PROTECTION AT THE SOURCE!! Inadequate wiring will cause a loss
of system performance and could be a fire and/or shock hazard.
110V: Use a 15Amp breaker and 12 AWG wire for 10.5 Amperes.
220V use a 10 Amp breaker and 12 AWG wire for 5.5 Amperes.
Amperage ratings assume a Pf of 60%. Actual measurements may vary.
Note: If the specified circuit breaker sizes are unavailable use the next higher rating
but do not exceed the specification by more then 10%. All wiring to be done to
applicable ABYC, Marine UL or CE standards.
Wire Sizing
Farallon 1800
Farallon 2800
220V use a 15 Amp breaker and 12 AWG wire for 7 Amperes.
Amperage ratings assume a Pf of 60%. Actual measurements may vary.