32
Maintenance
The Seawater Strainer
The sea water strainer’s stainless steel element should be inspected, removed, and cleaned
as needed. A clogged strainer will cause the MPC control to alarm
“Service Prefilters”
Be
careful to ensure that the thru-hull is closed before disassembly and the seal and element
are in place before reassembly. Put the screen up to a light for inspection. When the system
is put into storage, remove, rinse, and reassemble dry to impede corrosion. Check frequently
during operation.
The Prefilters
Service the prefilters as soon as possible after the prefilter condition graph begins to rise. If
the filter condition graph gets all the way to “Replace” the machine will slow down. When
display reaches “Replace” a second time the alarm sounds and the system will shut down to
prevent damage.
To service the filters shut off the thru-hull, open the housings, discard the old filters, Clean
out the housing bowls, reassemble the housings with new 20 and 5 micron filter elements.
The 5 micron filter goes downstream from the 20 micron. Leave dry until next startup.
Use only Spectra approved filters or you may void your warranty. Occasionally, lightly lube
the O-rings with silicone grease.
The Charcoal Fresh Water Flush Filter
Replace the charcoal filter element at least every 6 months.
General
Periodically inspect the entire system for leakage and chafe on the tubing and hoses. Repair
any leaks you find as soon as practical. Some crystal formation around the Spectra-Pearson
Pump blocks is normal. Wipe down any salt encrusted areas with a damp cloth.
Содержание Farallon 1800
Страница 2: ...2...
Страница 15: ...15 John Guest Super Speedfit Fittings...
Страница 39: ...39 Oil nipple threads and inside of hose with silicone oil or diluted soapy water DO NOT OIL HOSE COVER...
Страница 43: ...43...
Страница 44: ...44 Farallon 1800 Settings Farallon 2800 Settings...
Страница 45: ...45 Float Switch Wiring...
Страница 53: ...53...