7
Component Placement
Strainer
Mount the strainer in an accessible area close to the intake through-
hull that can handle water spillage during service. Extra care during
assembly must be taken to avoid air leaks from the strainer. Use the
supplied “Quick Block” and wire tie for mounting.
Boost Pump
The boost pump module should be mounted horizontally.
The boost pump, and the entire intake hose leading to it,
MUST
be installed below the water line to ensure that it
will prime.
Service Inlet Module
The service inlet module is mounted between the sea strainer and
the boost pump. It can be mounted in any orientation. Be sure that
once installed you will have access to the yellow valve handle on
top and the garden hose fitting on the side
The remote control panel can be mounted anywhere
that’s dry and convenient. Cut a 4-9/16” (116 mm) wide
by 2-7/8” (73mm) high opening for the panel. Locate in
an area that is easily visible and easy to manipulate the
buttons.
Use only Spectra approved remote cable.
The cable is not standard LAN cable or phone cord.
Remote Control Panel