* The distance is only valid in conjunction with a radiation protection plate on the top plate, which is fitted behind the vertical flue gas pipe.
Stoves
Distance to side wall
Distance to theback wall
Distance in the area of direct radiant heat of
the pane(s).
Dimensions of the fire protection floor
covering
A (cm)
B (cm)
C (cm)
D (cm)
combustible
No protection
required
combustible
No protection
required
combustible
No protection required
Length x width
Radius (with round floor
covering)
Piko S / Piko S RLU
10
10
10
5
80
80
50 x 30
50
Piko M / Piko M RLU
10
10
10
5
80
80
50 x 30
50
Piko L / Piko L RLU
10
10
10
5
80
80
50 x 30
50
Piko H
2
O
10
10
10
5
80
80
50 x 30
50
Cubo S / Cubo S RLU
10
10
10
5
80
80
50 x 30
50
Cubo M / Cubo M RLU
10
10
10
5
80
80
50 x 30
50
Cubo L / Cubo L RLU
10
10
10
5
80
80
50 x 30
50
Redoro S / M
10
10
10
5
80
80
50 x 30
50
Stovo S
31
20
16
5
80
80
50 x 30
50
Stovo S plus
31
20
16
5
80
80
50 x 30
50
Stovo M
31
20
16
5
80
80
50 x 30
50
Stovo L
56
25
13
5
80
80
50 x 30
50
Stovo L plus
64
25
13
5
80
80
50 x 30
50
Senso S / Senso S RLU
47
20
10 *
5
80
80
50 x 30
50
Senso M H
2
O
10
10
10
5
80
80
50 x 30
50
Senso L / Senso L RLU
45
10
15
5
80
80
50 x 30
50
Sino L
10
10
8
5
80
80
50 x 30
50
Sino City / Sino City RLU
36
10
7
5
80
80
50 x 30
50
Moro / Moro RLU
35
20
20
5
80
80
50 x 30
50
Noto
15
15
20
5
80
80
50 x 30
50
Passo XS / Passo XS RLU
15
15
5
5
80
80
50 x 30
50
Passo S / Passo S RLU
5
5
10
5
80
80
50 x 30
50
Passo M / Passo M RLU
5
5
10
5
80
80
50 x 30
50
Passo L / Passo L RLU
5
5
10
5
80
80
50 x 30
50