GB
4
1.1 CERTIFIED QUALITY
OUR STOVES ARE TESTED IN ACCORDANCE WITH DIN EN 13240. DECLA-
RATION OF PERFORMANCE IS AVAILABLE AND CAN BE VIEWED AT WWW.
SPARTHERM.COM
These stoves are equipped with a self-closing fire door which means the
door is only opened when the fireplace has to be serviced (e.g. to clean
the combustion chamber or add more fuel). For safety reasons, the closing
mechanism must not be tampered with; furthermore, any such action would
render the warranty and operating licence null and void. The guarantee and
operating licence are also rendered invalid if the customer modified the
technology of any other area of the stove.
1.1.1 SCOPE OF DELIVERY
• Fireplace made of Vermiculite / Schamotte
• Primary and secondary air supply
• Pull-out ash pan or ash box and grate (not all models)
• Self-closing fire door with high-temperature-resistant ceramic glass.
• Insulated glove*
• Rating plate („3.4 Type plate“ on page 29)
• Supplied pre-assembled in transport-friendly disposable cardboard
packaging
• Heat storage stones (only on CUBO M, PIKO M, SENSO L (optional), PASSO
M, STOVO M)
• Pump thermostat, thermal discharge safety device ¾", bleeder (only on
SENSO M H
2
O, PIKO H
2
O)
• Integrated cleaning system with control lever (only on PIKO H
2
O)
1.1.2 DAMAGE WHILE IN TRANSPORT
Immediately
on arrival, please check the goods delivered (visual inspec-
tion). Note down any possible damage on your delivery note and then please
1. GENERAL INSTRUCTIONS
Please consult your district master chimney sweep before assembling and
installing the stove. He will advise you of building law regulations, the
suitability of your chimney, and will conduct the acceptance procedure for
your stove. The chimney calculation is executed in accordance with DIN EN
13384 with the value triplet specified in this manual („9. Technical data“
on page 46).
Important for small children, elderly or infirm persons: As is the case with
all other heating devices, it is expedient that you attach a protective fixture
for these groups of persons, as the view pane and the cladding parts of the
stove can become extremely hot!
Danger of burn injuries!
Never touch the stove when the fire is burning or has just been extin-
guished! The stove should never be operated for an extended period of time
unattended.
The enclosed heat protection glove is exclusively designed to acti-
vate the operating handle and the “cold hand”. The glove is not
fire-proof!
National and European standards, the respective state-specific and local
directives and regulations, and the respective firing installation ordinance
of the German Federal State, must be complied with for setup and operation
of your stove and for the connection to the chimney.
The stove must always be operated with the door closed. Modification of the
closing device is prohibited!
* Important: The glove provided serves only as thermal protection and is not
fireproof.