After removing the top plate, the flue gas connection piece (C) (Fig. 10)
bolted onto the stove body is visible. Remove it by loosening the internal
hexagonal bolts (SW 13). Then, remove the back cover plate (Fig.
10
) using
the screw connection. A blanking plug for the flue gas outlet to the back/
side is visible (E) (Fig.
11
) behind the cover plate. Unscrew this.
Now fit the flue gas connection pipe depending on the desired orientation to
the right/left side or straight back. For the right/left side connection type, a
separate connecting piece is supplied with the Piko H20 stove (Fig.
13
). The
top connecting piece is used for the back connection type. Ensure that the
underlying caulking strip is placed correctly and seals tightly.
The removed dummy cover (E) is screwed in place as shown in (Fig.
12
) and
seals the flue gas outlet at the top.
Finally, close the open cladding openings at the back of the stove with the
enclosed cover plates and fit the top plate (Fig.
14
).
2.3.2 COMBUSTION AIR SUPPLY
The combustion air can be supplied in accordance with „2.3.2.1
Room-air-dependent“ and „2.3.2.3 Room-air-independent“ in different
ways.
2.3.2.1 ROOM-AIR-DEPENDENT
Your stove draws the combustion air from the installation area (room air depend-
ent operation). Ensure that the installation area is adequately supplied with
fresh air (more details in the country-specific FeuVO, DIN 18896, the technical
regulations, etc.). The fresh air supply must be checked by the installer and the
operator. When operating several fireplaces in a single room or linked space,
ensure that sufficient air is available for complete combustion! It is possible that
there is not a sufficient supply of fresh air if the windows and doors are sealed
(e.g., in combination with energy saving measures). As a result, the ventilation
of the tiled stove can be affected. This can adversely affect your well-being
and, potentially, your safety. If necessary, an air valve must be installed near
the pellet stove for the additional supply of fresh air, or a combustion air line
must be routed outwards („2.3.2.2 Separate combustion air supply“) or in a
well-ventilated room (except for the heating room). In particular, ensure that the
Outlet on the left side
A
B
C
D
E
Outlet to the centre
A
B
C
D
E
Outlet on the right side
A
B
C
D
E
A
B
C
D
E
Fig. 9
A
B
C
D
E
Fig. 10
A
B
C
D
E
Fig. 11
A
B
C
D
E
Fig. 12
A
B
C
D
E
Fig. 13
A
B
C
D
E
Fig. 14