58
Chapter 6 Appendix
1.
Specific parameters
Model
ST9010 series single channel parameters
Withstanding voltage test
Output
Voltage
AC
range
0.050kV—5.000kV
waveform
Sinusoidal Wave
distortion
< 3%
frequency
50, 60Hz selectable
accuracy
±1%
Output power
50VA (5.000kV 10mA)
Voltage
regulation
±(1.0% +50V) (rated power)
DC
range
0.050 kV—6.00kV
Source frequency
600Hz
Output power
25VA (5.000kV 5mA)
Voltage
regulation
± (1.0% +100V) (rated power)
Voltage resolution
1V
Voltage output accuracy
± (2.0% 5V) (no load)
Voltage generation method
DDS signal source plus PWM amplifier
Current
test range
AC
Current range
0.001mA – 10mA
SC current
(moment)
>20 mA
(setted output voltage >500V)
Current
resolution
0.001 mA
Current accuracy
± (2% r5 digits)
Actual current
OFF-0.001 mA-10mA
DC
Current range
0.1uA – 5.00mA
Current accuracy
± (2.0% r5 digits)
Discharge Function
Automatic discharge after the test (DCW)
IR Test
Output Voltage
0.050V – 1.000V
Voltage Resolution
1V
Voltage Accuracy
± (1.0% range+5V)
Max. Output Current
5mA
Max. Output Power
5VA (1000V/5mA)
Output instantaneous short circuit
current
>10mA (Setted output voltage>500V)
Load Adjustment Rate
≤1% (rated power)
Ripple
(
1kV
)
≤3% (1kV, no load)