Useful notes/tips and tricks
17
17
Instead of setting the flow rate for the system using a flow rate
limiter, it is better to adjust the flow rate using the switch on the
pump and by means of the
“
max. speed
”
setting on the controller
(see 12.9.4). This saves electricity!
The service values (see 15.) include not only current measurement
values and operating states, but also all of the settings for the con-
troller. Write the service values down just once after commissioning
has been successfully completed.
In the event of uncertainty as to the control response or malfunctions
the service values are a proven and successful method for remote
diagnosis. Write the service values down (see 15.) at the time that
the suspected malfunction occurs. Send the service value table
by fax or e-mail with a brief description of the error to the specialist
or manufacturer.
In program 13
“
Solar with storage tank and pool
”
the charging of
the pool, e.g. for winter operation, can be switched off using a
simple function. To do this, simply press and hold the
“
esc
”
key down
for several seconds on the diagram/overview screen. A message
appears on the display as soon as the pool is switched off or when
the pool is switched on again.
In program 1
“
Solar with storage tank
”
the mechanical relay R2
switches together with the speed-controlled output R1. Relay out-
put R2 can be used to operate larger loads up to 460VA, as well
as valves or auxiliary relays with low power.