17
Menu “3. Times” is used to set the time,
date, operating times for the heating
circuit.
Caution
The menu is closed by pressing “esc” or
selecting “Exit display mode”.
The associated temperature
reference values are speci
fi
ed
in menu 5 “Settings”!
This menu is used to select the daytime mode times for the heating circuit; three time
periods can be speci
fi
ed for each weekday and copied over to the following days.
Setting range: Three time ranges for each day of the week
Default: Mo-Su 6:00-22:00
Note: See 5. for the associated temperature settings
3.2. - Heating circuit day
3. - Times
Times
This menu is used to set the current time and date.
3.1. - Time & Date
For proper functioning of the controller and statistics for the system data
it is essential for the time to be set accurately on the controller. Please
note that the clock continues to run for about 24 hours if the mains volt-
age is interrupted, and after that has to be reset.
Caution
This menu can be used to select a time range for each day of the week in which the
heating circuit is supplied with an increased comfort temperature, e.g. for quick heating
in the morning.
Setting range: One time range for each day of the week
Default: Mo-Su off
Note: See 5. for the associated temperature settings.
3.3. - Heating Comfort
Times that are not speci
fi
ed are automatically considered to be night-
time mode. The set times are only taken into account in the heating
circuit operating mode “Automatic”
Caution
This menu is used to select the Cooling mode times; three time periods can be speci-
fi
ed for each weekday and copied over to the following days.
Setting range: Three time ranges for each day of the week
Default: Mo-Su Off
Note: See 6. for the associated temperature settings
3.4. - Cooling times