Appendices
Maximum Log File size
This value limits the size of the PowerKey Log file, which is
created by the Add to Log Action (see below). When an entry
is added to the log file which would make it exceed this value,
the topmost (oldest) items are removed.
If you limit the size of the PowerKey Log file to less than 32K, it will
never grow too large to be opened by SimpleText.
New Triggers
When System Crashes
This Trigger activates whenever the computer crashes. When
the computer is running normally, the PowerKey software
“pings” the hardware every 10 seconds. If this communication
fails for a period of time (specified in the Preferences dialog
box), the hardware will execute any When System Crashes
Events in the Schedule.
If more than one When System Crashes Events exist in the Schedule,
only the first one encountered will be executed. You can use Qualifi-
ers if you wish PowerKey to react differently at different times or on
different days.
When Timer Expires
This Trigger activates whenever the User Timer counts down
to zero. The User Timer is maintained by the PowerKey
software for use by custom programs when you want greater
control over crash detection. You can set the value of this timer
via an Apple Event or script; see below for more information.