3-3 (E)
ZRD-1/ZRD-2/ZRCT-100/ZRCT-200
3-2. Rack
Mounting
The display controller can be mounted on a 19-inch standard rack.
w
.
Be sure to use the specified rack mount kit.
If not, injury may result and the equipment may fall due to insufficient strength.
.
After rack mounting, be sure to tighten the screws on the rack angle and fix the display controller in the
rack.
If the screws on the rack angle are not tightened, the display controller may slip from the rack and fall,
causing injury.
n
To reduce the temperature rise inside the display controller, keep at least 20 cm in the rear between the
rack and display controller.
3-2-1. Required Equipment/Tools
Supplied accessories
.
Rack bracket L 4-579-760-01: 1 pc
.
Rack bracket R 4-579-761-01: 1 pc
.
Screws (B4
x
6) 7-682-560-09: 4 pcs
Other items to be prepared (available separately)
.
EIA standard 19-inch rack mount: 1 set
Depth: 700 mm to 900 mm
t
This is the depth required to install the rack mount kit RMM-10.
.
Rack mount kit RMM-10:
1 set
.
Rack mounting screws (B5
x
12: 7-682-576-09) 4 pcs