ZRD-1/ZRD-2/ZRCT-100/ZRCT-200
2. Turn the shafts to the half-locked state. (Refer to step 5-(3) in Section 2-4-5.)
3. Adjust the display unit in the Z direction by visually checking the array from the front side.
n
When the hexagon wrench does not move smoothly during the adjustment, a large load may be
applied to the joint coma. If you continue the adjustment as it is, the joint coma may be damaged.
When the hexagon wrench does not move smoothly, loosen the lock furthermore instead of moving
the wrench forcibly.
The joint coma cannot be replaced if it is damaged. Adjust carefully so as not to break the joint coma.
4. Lock the shafts.
5. Remove all eccentric pins (short) and hexagon wrenches.
Fine adjustment in the Z direction using the adjustment plate
If a joint stays visible on the both sides or the center of the display unit even though you perform the step
1 to step 5 as described previously, you can perform the additional fine adjustment using the adjustment
plate supplied with the display unit.
n
The fine adjustment using the adjustment plate can be made only in the Z direction between the display
units as shown in the figure.
If a joint stays visible on the other portion in the Z direction, perform step 1 to step 5 as described previ-
ously again.
Required items
Supplied accessories
.
Adjustment plate
1 pc
.
Adjustment screw
1 pc
.
Hexagon socket bolt 1 pc
Tools
.
Ball-pointed hexagon wrench (subtense: 5 mm)
.
Torque driver (3 N
.
m)
For this line, you can make the
fine adjustment in the Z direction
using the adjustment plate.
Center
Both sides
Display units
Display units