4-19
UP-D70XR
e)
RIBBON ERROR
Detection sensor : Take up FG sensor (Photo interrupter) and supply FG sensor (Photo interrupter)
Cause
: It was judged that ribbon is stopped by both FG sensors during beginning
detection of ribbon.
Symptom
: 1.
Ribbon is jammed.
2.
Ribbon is cut at the halfway.
3.
Paper or ribbon is stopped at the halfway.
4.
Sensor defective
5.
Take up ribbon motor does not operate.
6.
Take up ribbon motor rotate slowly.
f)
HEAD IN COOLING/HEAD IN HEATING
Detection sensor : Head thermistor
Cause
: Head temperature is less than 15
d
C or more than 60
d
C
Symptom
: 1.
Head temperature is over than possible printing temperature range (15 to 60
d
C).
2.
Head thermistor defective
3.
Head harness defective
g) HEAD CABLE NOT CONNECTED (This is not described in users manual.)
Detection sensor : Head thermistor
Cause
: Head temperature can not be measured.
Symptom
: 1.
Head thermistor defective
2.
Head harness defective
Содержание UP-D70XR
Страница 1: ...DIGITAL COLOR PRINTER UP D70XR SERVICE MANUAL Volume 1 1st Edition ...
Страница 4: ...2 UP D70XR 6 Troubleshooting 6 1 Mechanical Section 6 1 6 2 Electrical Section 6 3 ...
Страница 6: ......
Страница 27: ...1 21 UP D70XR 80 Divers Sony Corporation Printed in Japan ...
Страница 28: ......
Страница 50: ......
Страница 84: ......
Страница 94: ......