– 12 –
5.
Flange Back Check
Switch setting
1) DIGITAL ZOOM (Menu screen) ....... OFF
2) STEADY SHOT (Menu screen) ......... OFF
3) FOCUS ................................................ AUTO
Note:
When Auto Focus is ON, whether the focus is in order or disordered can be judged from the data displayed on page 01.
1) Select page: 06, address: 04, and set data: 0F, then press the
y
key.
2) The focusing condition can be confirmed from the data displayed on page 01.
01-00-XX
Odd number : Focus is in order.
Even number : Focus is disordered.
Checking method
Steps
Page
Address
Data
Work Description
1
Place the Siemens star at 2.0 m forward position from the lens front surface. As the iris is
in open state, lower the luminance of Siemens star to the extent that noise does not appear
on the monitor TV.
2
Shoot the Siemens star with the zoom at TELE end.
3
Check that the focus is in order. (Note)
4
06
21
10
Press the
y
key.
5
Shoot the Siemens star with the zoom at WIDE end.
6
Check on the monitor screen that the focus is in order.
Processing after completion of check
Steps
Page
Address
Data
Work Description
1
06
21
00
Press the
y
key.
2
06
04
00
Press the
y
key.
Subject
Siemens star (reflection type)
(Located at 2.00 m position from lens front surface)
(Luminance: about 200 lux)
Measurement point
Check on monitor TV
Measuring instrument
(Camera-through screen)
Adjustment value
Focus must be in order at TELE end and WIDE end
Содержание MDDISCAM DCM-M1
Страница 5: ...1 1 SECTION 1 GENERAL This section is extracted from in struction manual 3 866 152 11 DCM M1 ...
Страница 6: ...1 2 ...
Страница 7: ...1 3 ...
Страница 8: ...1 4 ...
Страница 9: ...1 5 ...
Страница 10: ...1 6 ...
Страница 11: ...1 7 ...
Страница 12: ...1 8 ...
Страница 13: ...1 9 ...
Страница 14: ...1 10 ...
Страница 15: ...1 11 ...
Страница 16: ...1 12 ...
Страница 17: ...1 13 ...
Страница 18: ...1 14 ...
Страница 19: ...1 15 ...
Страница 20: ...1 16 ...
Страница 21: ...1 17 ...
Страница 22: ...1 18 ...
Страница 23: ...1 19 ...
Страница 24: ...1 20 ...
Страница 25: ...1 21 ...
Страница 26: ...1 22 ...
Страница 27: ...1 23 ...
Страница 28: ...1 24 ...
Страница 29: ...1 25 ...
Страница 30: ...1 26 ...
Страница 31: ...1 27 ...
Страница 32: ...1 28 ...
Страница 33: ...1 29 ...
Страница 34: ...1 30 1 30 E ...
Страница 47: ...2 13 MEMO ...
Страница 69: ...DCM M1 4 5 4 6 4 7 4 8 4 1 FRAME SCHEMATIC DIAGRAM FRAME ...
Страница 96: ...DCM M1 4 115 4 113 4 114 ETHER INTERFACE ETHER ...
Страница 98: ...DCM M1 4 119 4 120 AV IN OUT JACK JACK AV IN OUT SCHEMATIC DIAGRAM See page 4 121 for printed wiring board ...
Страница 99: ...DCM M1 4 121 JACK AV IN OUT PRINTED WIRING BOARD Ref No JACK board 20 000 series 4 122 AV IN OUT JACK ...
Страница 173: ...DCM M1 33 34 35 LCD LCD Signal Paths were Missing in Service Manual LCD LCD SCHEMATIC DIAGRAM Page 4 106 to 4 108 ...
Страница 196: ... 22 FOR CAMERA OPTICAL AXIS ADJUSTMENT 0 180 90 67 5 22 5 337 5 292 5 247 5 202 5 157 5 112 5 8 4 5 7 1 6 2 3 270 ...