– 10 –
5. Brightness Adjustment
Set the VIDEO signal level that drives the LCD to proper value.
If deviated, the LCD screen will be unclear, black blurring, or white
blurring.
Item number
3-01-04
Screen display
10-step gradation pattern (white/black)
Measurement point
Adjusting monitor jig
G
pin (VG)
Measuring instrument
Oscilloscope
Adjustment data
7C
initial value
Adjustment value
A = 1.40
±
0.05 Vp-p
Note:
This is the tracking adjustment in relation to “6. Contrast
Adjustment”.
Adjusting method
1) Select major item number “2” (EVF), and set the 10-step gra-
dation pattern (white/black).
2) Select the item number “3-01-04”.
3) Press the DSPL key to display the 10-step gradation pattern
(white/black) on the LCD screen.
4) Connect the adjusting monitor jig
A
pin (XTST) and
E
pin
(GND).
5) Using
e
and
E
keys, change the adjustment data so that the
voltage (A) between pedestal (0 IRE) and GAMMA1 limiter
level satisfies the adjustment value.
6) Press
y
key to write the adjustment data.
7) Disconnect the adjusting monitor jig
A
pin (XTST) and
E
pin (GND).
8) Press the DSPL key to return the LCD screen to the test mode
screen.
9) Check that the adjustment value of “Contrast Adjustment” is
satisfied.
If not satisfied, perform “Contrast Adjustment”.
Fig.7-1-13
Pedestal(0 IRE)
GAMMA1
limiter level
A
2H
4. RGB D Range Adjustment
Set the D range of RGB decoder driver step-wise output that drives
the
LCD to proper value.
If deviated, the LCD screen will be black blurring or white blur-
ring.
Item number
3-01-03
Screen display
10-step gradation pattern (white/black)
Measurement point
Adjusting monitor jig
G
pin (VG)
Measuring instrument
Oscilloscope
Adjustment data
80
initial value
Adjustment value
A = 3.00
±
0.05 Vp-p
Adjusting method
1) Select major item number “2” (EVF), and set the 10-step gra-
dation pattern (white/black).
2) Select the item number “3-01-03”.
3) Press the DSPL key to display the 10-step gradation pattern
(white/black) on the LCD screen.
4) Using
e
and
E
keys, change the adjustment data so that the
voltage (A) between pedestal of inverted waveform and ped-
estal of non-inverted waveform satisfies the adjustment value.
5) Press
y
key to write the adjustment data.
6) Press the DSPL key to return the LCD screen to the test mode
screen.
Fig.7-1-12
2H
Pedestal
Pedestal
A
Содержание MDDISCAM DCM-M1
Страница 5: ...1 1 SECTION 1 GENERAL This section is extracted from in struction manual 3 866 152 11 DCM M1 ...
Страница 6: ...1 2 ...
Страница 7: ...1 3 ...
Страница 8: ...1 4 ...
Страница 9: ...1 5 ...
Страница 10: ...1 6 ...
Страница 11: ...1 7 ...
Страница 12: ...1 8 ...
Страница 13: ...1 9 ...
Страница 14: ...1 10 ...
Страница 15: ...1 11 ...
Страница 16: ...1 12 ...
Страница 17: ...1 13 ...
Страница 18: ...1 14 ...
Страница 19: ...1 15 ...
Страница 20: ...1 16 ...
Страница 21: ...1 17 ...
Страница 22: ...1 18 ...
Страница 23: ...1 19 ...
Страница 24: ...1 20 ...
Страница 25: ...1 21 ...
Страница 26: ...1 22 ...
Страница 27: ...1 23 ...
Страница 28: ...1 24 ...
Страница 29: ...1 25 ...
Страница 30: ...1 26 ...
Страница 31: ...1 27 ...
Страница 32: ...1 28 ...
Страница 33: ...1 29 ...
Страница 34: ...1 30 1 30 E ...
Страница 47: ...2 13 MEMO ...
Страница 69: ...DCM M1 4 5 4 6 4 7 4 8 4 1 FRAME SCHEMATIC DIAGRAM FRAME ...
Страница 96: ...DCM M1 4 115 4 113 4 114 ETHER INTERFACE ETHER ...
Страница 98: ...DCM M1 4 119 4 120 AV IN OUT JACK JACK AV IN OUT SCHEMATIC DIAGRAM See page 4 121 for printed wiring board ...
Страница 99: ...DCM M1 4 121 JACK AV IN OUT PRINTED WIRING BOARD Ref No JACK board 20 000 series 4 122 AV IN OUT JACK ...
Страница 173: ...DCM M1 33 34 35 LCD LCD Signal Paths were Missing in Service Manual LCD LCD SCHEMATIC DIAGRAM Page 4 106 to 4 108 ...