3-17
HDW-250
3-2. DIAG Menu
...............
...............
...............
...............
...............
...............
...............
...............
Audio Meter LCD
Description
THREAD
Checking the threading operation and the threading sensor.
F. FWD button is pressed : Threading is executed.
REW button is pressed :
Unthreading is executed.
THREAD :
0
Thread sensor
1 : Sensor is working
0 : Sensor is not working
UNTHREAD :
1
Unthread sensor
1 : Sensor is working
0 : Sensor is not working
S REEL
Checking the S reel motor.
F. FWD button is pressed : Rotates in the clockwise direction. (Hexadecimal number increases.)
REW button is pressed :
Rotates in the counterclockwise direction.
(Hexadecimal number decreases.)
STOP button is pressed :
Stops.
xxxx
(Hexadecimal data)
T REEL
Checking the T reel motor.
F. FWD button is pressed : Rotates in the clockwise direction. (Hexadecimal number increases.)
REW button is pressed :
Rotates in the counterclockwise direction.
(Hexadecimal number decreases.)
STOP button is pressed :
Stops.
xxxx
(Hexadecimal data)
CAPSTAN
Checking the capstan motor.
F. FWD button is pressed : Rotates in the clockwise direction. (Hexadecimal number increases.)
REW button is pressed :
Rotates in the counterclockwise direction.
(Hexadecimal number decreases.)
STOP button is pressed :
Stops.
xxxx
(Hexadecimal data)
DRUM
Checking the drum motor.
F. FWD button is pressed : Drum rotates. (Checking starts.)
STOP button is pressed :
Drum stops.
SPEED :
1
0 : NG
PHASE :
1
1 : OK
PG :
1
ADJUST
For the servo system adjustment (Refer to Section “5-3. Servo System Adjustment” of Maintenance
Manual Part 2 Vol. 1.)
TRACON VR
Correction of the clicking position of the TRACKING control VR
CAP FG DUTY
Capstan FG duty adjustment
CAP SPEED
Capstan free speed adjustment
DRUM PG
Drum PG phase adjustment
EXIT
MVRAM CONTROL
Saving the servo system adjustment data
(Refer to Section “5-3. Servo System Adjustment” of Maintenance Manual Part 2 Vol. 1.)
NVRAM INITIAL
Initialization of adjustment data
SV DATA SAVE
Registration (saving) the servo data
EXIT