3-10
HDW-250
3-1. Setup Menu
SYSTEM
Display on LCD
Setup item
Sub item
Setup value
Description
V TEST SG
VIDEO
OFF
Selects a test signal that is going to be output from the VTR’s
TEST SG
CB (100 % Color Bar) internal signal generator.
RMP(Ramp)
OFF :
Test signal is not generated. VTR performs
TEN(Ten Steps)
the ordinary operation.
GRY(Gray)
Other than OFF : The selected test signal is output to VTR.
The test signal can also be recorded.
A TEST SG
AUDIO
OFF
Selects operation of the internal audio test signal generator.
TEST SG
1K/1
OFF : The audio test signal generator is not operated.
1K/2
1K/1 : 1 kHz (In this case, the sine wave signal of 1 kHz at
_
18 dB FS is supplied to all audio inputs.)
1K/2 : 1 kHz (In this case, the sine wave signal of 1 kHz at
_
20 dB FS is supplied to all audio inputs.)
CAM POWER
CAMERA
ON
Sets whether or not to supply the power from VTR to the camera
POWER
OFF
that is connected via 26-pin connector.
SUPPLY
ON : Power is supplied.
OFF : Power is not supplied.
DISPLAY
Sets whether or not to select a display by pressing the DISPLAY
SELECT
button of the display window operational buttons.
IN/OUT SIG
IN/OUT
ON
Sets whether or not to select the video input/output meter
SIGNAL
OFF
display using the DISPLAY button of display window operational
buttons.
ON : Selects the video input/output meter display by the
DISPLAY button of display window operational buttons.
OFF : Not selects the video input/output meter display by the
DISPLAY button of display window operational buttons.
INFORMATI
INFORMATION ON
Sets whether or not to select the information display using the
OFF
DISPLAY button of display window operational buttons.
ON : Selects the information display by the DISPLAY
button of display window operational buttons.
OFF : Not selects the information display by the DISPLAY
button of display window operational buttons.
ERROR LOG
ERROR
ON
Sets whether or not to select the error log display using the
LOG
OFF
DISPLAY button of display window operational buttons.
ON : Selects the error log display by the DISPLAY button
of display window operational buttons.
OFF : Not selects the error log display by the DISPLAY
button of display window operational buttons.
RF CHECK
RF
ON
Sets whether or not to select the RF check display using the
CHECK
OFF
DISPLAY button of display window operational buttons.
ON : Selects the RF check display by the DISPLAY button
of display window operational buttons.
OFF : Not selects the RF check display by the DISPLAY
button of display window operational buttons.
CHANNEL
CHANNEL
ON
Sets whether or not to select the channel condition display using
CONDITION OFF
the DISPLAY button of display window operational buttons.
ON : Selects the channel condition display by the DISPLAY
button of display window operational buttons.
OFF : Not selects the channel condition display by the
DISPLAY button of display window operational buttons.
The items that are surrounded by square (
[|]