3-15
HDW-250
3-2. DIAG Menu
RF TROUBLE
Audio Meter
LCD
Description
CANCEL EDIT
3
Sets the items that do not issue the log and warning indication. The numeral indicates where the item
with the cursor is located.
*
LOST LOCK
The items to which the asterisk (
*
) is given by pressing the SET button, do not issue log or warning
NO EXT REF V
display.
*
BATTERY NEAR
BATTERY END
TAPE NEAR
CANCEL TOTAL :02
Total number of items that are set to be canceled.
DISP MODE
Setting the log indication mode
DISP TIME
TC
Time data of log indication
TC : time code
REAL : Real time
ERROR
ON
Error indication by log
ON : Error is displayed.
OFF :
Error is not displayed.
WARNING
ON
Warning indication by log
ON : Displayed.
OFF :
Not displayed.
CONDITION
ON
Condition indication by log
ON : Displayed.
OFF :
Not displayed.
Example : When you want to check only the error items of the logs, set ON to the ERROR only and observe
the logs.
DATE
’XX/XX/XX
Setting year, month and day.
SET :
SET
DISPLAY : CANCEL
Hours are set by the front time code setting block.
TEST
Test menu
<PROC>
Tests the processor
<TTP>
Adjusts the TTP system
PROC
SYSTEM EE
OFF
Selects the bypass mode of digital signal (for check).
(Refer to the Overall Block Diagram in the Section 4.)
OFF : Normal operating mode
SYS1 : SYSTEM EE 1 mode
SYS2 : SYSTEM EE 2 mode
SYS3 : SYSTEM EE 3 mode
SYS4 : SYSTEM EE 4 mode
525 TEST SG
OFF
Internal test signal for down converter output
OFF : Not output
CB :
100 % Color Bar (DCP)
RMP : Ramp
TEN : Ten Step (DCP)
MLT : MULTI BURST (DCP)
PBR : PULSE & BAR (DCP)
EXIT
......
...............
...............
...............
...............
...............
...............
...............
...............
...............
...............