5-45
6.7 msec
PB RF signal is stable
Pin
qj
Pin
w;
Fig. 5-3-4.
4-2. AGC Center Level Adjustment (VC-265 board)
Mode
Playback
Signal
Recorded signal at “Preparations
before adjustments”
Measurement Point
Pin
w;
of CN004 (RF MON) (Note 1)
Ext. trigger: Pin
qj
of CN004 (SWP)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
1E
Specified Value
The data of page: 3, address: 03 is
“00”
Note 1:
Connect a 75
Ω
resistor between Pin
w;
and Pin
ql
(GND) of
CN004.
75
Ω
resistor (Parts code: 1-247-804-11)
Adjusting method:
Order Page Address Data
Procedure
1
Playback the recorded signal at
“Preparations before
adjustments”
2
0
01
01
Set the data.
3
3
33
08
Set the data.
4
Confirm that the playback RF
signal is stable. (Fig. 5-3-4.)
5
3
01
23
Set the data, and press PAUSE
button.
6
3
02
Check that the data is “00”.
7
3
03
Check that the data is “00”.
(Note2)
8
Perform “APC & AEQ
Adjustment”.
Note2:
If the data of page: 3, address: 03 is other than “00”, adjustment
has errors. (Take an appropriate remedial measures according to
the errors referring to the following table.)
Data
Contents of defect
20
Perform re-adjustment. (Note 3)
30
The machine is defective
40
Perform re-adjustment. (Note 3)
50
The machine is defective
Note 3:
If this data is displayed twice successively, the machine is defective.
4-3. APC & AEQ Adjustment (VC-265 board)
Mode
Playback
Signal
Recorded signal at “Preparations
before adjustments”
Measurement Point
Pin
w;
of CN004 (RF MON) (Note 1)
Ext. trigger: Pin
qj
of CN004 (SWP)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
18, 19, 1B, 1C, 21, 2C
Specified Value
The data of page: 3, address: 03 is
“00”
Note 1:
Connect a 75
Ω
resistor between Pin
w;
and Pin
ql
(GND) of
CN004.
75
Ω
resistor (Parts code: 1-247-804-11)
Note 2:
The “AGC Center Level Adjustment” must have already been
completed before starting this adjustment.
Adjusting method:
Order Page Address Data
Procedure
1
Playback the recorded signal at
“Preparations before
adjustments”
2
0
01
01
Set the data.
3
3
33
08
Set the data.
4
Confirm that the playback RF
signal is stable. (Fig. 5-3-5.)
5
3
01
07
Set the data, and press PAUSE
button.
6
3
02
Check that the data changes
from “07” to “00” in about 20
seconds after pressing PAUSE
button.
7
3
03
Check that the data is “00”.
(Note3)
8
Perform “Processing after
Completing Adjustments”.
Note3:
If the data is other than “00”, adjustment has errors. Take an
appropriate remedial measures according to the errors referring to
the following table.
Data
Contents of defect
20
Perform re-adjustment. (Note 4)
30
The machine is defective
50
Perform re-adjustment. (Note 4)
60
The machine is defective
80
The machine is defective
Note 4:
If this data is displayed twice successively, the machine is defective.
Fig. 5-3-5.
6.7 msec
PB RF signal is stable
Pin
qj
Pin
w;
Содержание Handycam DCR-PC6E
Страница 102: ...5 1 DCR PC6E PC9 PC9E SECTION 5 ADJUSTMENTS ...
Страница 172: ... Take a copy of OPTICAL AXIS FRAME with a clear sheet for use 198 OPTICAL AXIS FRAME ...
Страница 174: ...DCR PC6E PC9 PC9E 200 9 929 899 31 Sony EMCS Co Kohda TEC 2001E1600 1 2001 5 Published by PV Customer Center ...
Страница 175: ...Revision History Ver 1 0 Date 2001 05 History Official Release Contents S M Rev issued 992989931 pdf Reverse ...