5-24
11. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(Color reproduction adjustment
frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
Display data of page 1 (Note3)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
40, 41
Specified Value
R ratio: 2C50 to 2D50
B ratio: 5C00 to 5D00
Note1:
After the power is turned on, this adjustment can be done only
once.
Note2:
Perform “Auto White Balance & LV Standard Data Input” before
this adjustment.
Note3:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu display) ................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the
lens.
2
0
01
01
Set the data.
3
F
42
Write down the data.
4
F
42
2C
Set the data, and press PAUSE
button.
5
F
43
Write down the data.
6
F
43
D0
Set the data, and press PAUSE
button.
7
F
44
Write down the data.
8
F
44
5C
Set the data, and press PAUSE
button.
9
F
45
Write down the data.
10
F
45
80
Set the data, and press PAUSE
button.
11
6
01
83
Set the data, and press PAUSE
button.
12
6
01
81
Set the data, and press PAUSE
button.
13
6
02
Check that the data changes to
“01”. (Note4)
14
6
01
3F
Set the data, and press PAUSE
button.
15
6
04
04
Set the data.
16
1
Check that the display data
(Note3) satisfies the R ratio
specified value.
17
6
04
05
Set the data.
18
1
Check that the display data
(Note3) satisfies the B ratio
specified value.
Note4:
The adjustment data will be automatically input to page: F, address:
40, 41.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
04
00
Set the data.
3
F
42
Set the data that is written down
at step 3, and press PAUSE
button.
4
F
43
Set the data that is written down
at step 5, and press PAUSE
button.
5
F
44
Set the data that is written down
at step 7, and press PAUSE
button.
6
F
45
Set the data that is written down
at step 9, and press PAUSE
button.
7
0
01
00
Set the data.
RadarW
RadarW
RadarW
RadarW
RadarW
Содержание Handycam DCR-PC6E
Страница 102: ...5 1 DCR PC6E PC9 PC9E SECTION 5 ADJUSTMENTS ...
Страница 172: ... Take a copy of OPTICAL AXIS FRAME with a clear sheet for use 198 OPTICAL AXIS FRAME ...
Страница 174: ...DCR PC6E PC9 PC9E 200 9 929 899 31 Sony EMCS Co Kohda TEC 2001E1600 1 2001 5 Published by PV Customer Center ...
Страница 175: ...Revision History Ver 1 0 Date 2001 05 History Official Release Contents S M Rev issued 992989931 pdf Reverse ...