Chapter 4
Time Data and Sub LCD Menu
Chapter 4
Time Data and Sub LCD Menu
71
General settings page (1)
General Settings Pages of the Sub LCD Menu
There are general settings pages (1) and (2).
TC GENERATOR
PRESET
KEY INH
OFF
F-RUN
PB/EE
DF
REMOTE
9P
VITC ON
CHARACTER
ON
1
PRESET/REGEN (regenerate) setting
2
F-RUN/R-RUN (free-run/rec-run) setting
5
CHARACTER setting
4
VITC setting
6
REMOTE setting
7
PB/EE (monitor signal) setting
8
KEY INH (key inhibit) setting
3
DF/NDF (drop-frame/non-drop-frame) setting
(for DSR-70A only)
1
PRESET/REGEN (regenerate) setting
Select the value set in the internal timecode generator.
PRESET:
Preset the initial value of the timecode
generated by the internal timecode generator,
either by a control panel operation or by remote
control from the device connected to the
REMOTE connector.
REGEN:
Synchronize the internal timecode
generator with the timecode read by the internal
timecode reader.
2
F-RUN/R-RUN (free-run/rec-run) setting
Select the progression method for the timecode
generated by the internal timecode generator.
F-RUN:
Timecode progresses continuously from the
time when this unit is powered on, regardless of
the unit's operating status.
R-RUN:
Timecode progresses only during recording.
3
DF/NDF (drop-frame/non-drop-frame) setting
(for DSR-70A only)
Select DF to advance timecode in drop-frame mode,
and NDF to advance timecode in non-drop-frame
mode.
4
VITC setting
Set to ON to record the VITC timecode generated by
the internal timecode generator.
When this is set to OFF, the internally generated VITC
timecode is not recorded, but the VITC timecode
inserted in the input video signal is recorded as it is.
5
CHARACTER setting
Set to ON to superimpose text information such as
timecode, menu settings and alarm messages on the
video signal output from the VIDEO OUTPUT 2
(SUPER) connector.
6
REMOTE setting
When the REMOTE/LOCAL switch is set to
REMOTE, select the source for control of this unit.
9P:
The unit is controlled from the device connected
to the REMOTE connector (D-sub9-pin).
i.LINK:
The unit is controlled from the device
connected to the DV IN/OUT connector (DSBK-
140/160A).
7
PB/EE (monitor signal) setting
Select the video/audio signal output when the tape is
being fast forwarded or rewound, or when the unit is
stopped or on standy .
PB:
Playback signal
PB/EE:
Input signal in E-E mode