5-22
DCR-TRV240/TRV340
6. Picture Frame Setting
Subject
Color bar chart
(Color reproduction adjustment frame)
(1.5m from the front of the lens)
Measurement Point
Video output terminal
Measuring Instrument
Oscilloscope and TV monitor
Specified Value
A=B, C=D, E=F
Note1:
The following adjustments should be carried out upon completion
of “Flange back adjustment”.
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu display) ................................... OFF
4)
STEADY SHOT (Menu display) ..................................... OFF
Setting method:
1)
Select page: 6, address: 48, and set data: 01.
2)
Adjust the zoom and the camera direction, and set to the
specified position.
3)
Mark the position of the picture frame on the monitor display,
and adjust the picture frame to this position in following
adjustments using “Color reproduction adjustment frame”.
Processing after Completing Camera System Adjustments:
After completing the camera system adjustments, release the data
settings.
1)
Select page: 6, address: 48, and set data: 00.
Check on the oscilloscope
1. Horizontal period
Fig. 5-1-9.
2. Vertical period
Fig. 5-1-10.
Check on the monitor TV (Underscanned mode)
Fig. 5-1-11.
A=B
C=D
A
B
C
D
E=F
V
E
F
Color bar chart picture frame
Monitor TV picture frame
Содержание DCR-TRV240
Страница 102: ...5 1 DCR TRV240 TRV340 SECTION 5 ADJUSTMENTS ...
Страница 177: ... Take a copy of OPTICAL AXIS FRAME with a clear sheet for use 206 OPTICAL AXIS FRAME DCR TRV240 TRV340 ...
Страница 179: ...DCR TRV240 TRV340 208 Sony EMCS Co 2002A1600 1 2002 1 Published by DI Customer Center 9 929 932 31 ...
Страница 180: ...Revision History Ver 1 0 Date 2002 01 History Official Release Contents S M Rev issued 992993231 pdf Reverse ...