5-24
DCR-TRV240/TRV340
9. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
Display data of page 1 (Note3)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
2E, 2F
Specified Value
R ratio: 2BC0 to 2CC0
B ratio: 5920 to 5A20
Note1:
This adjustment should be carried out upon completion of “Auto
White Balance & LV Standard Data Input”.
Note2:
After the power is turned on, this adjustment can be done only
once.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu display) ................................... OFF
4)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the lens.
2
0
01
01
Set the data.
3
6
48
01
Set the data.
4
F
3E
Write down the data.
5
F
3E
2C
Set the data, and press PAUSE
button.
6
F
3F
Write down the data.
7
F
3F
40
Set the data, and press PAUSE
button.
8
F
40
Write down the data.
9
F
40
59
Set the data, and press PAUSE
button.
10
F
41
Write down the data.
11
F
41
A0
Set the data, and press PAUSE
button.
12
6
01
83
Set the data, and press PAUSE
button.
13
6
01
81
Set the data, and press PAUSE
button.
14
6
02
Check that the data changes to
“01”. (Note5)
15
6
01
3F
Set the data, and press PAUSE
button.
16
0
03
04
Set the data.
17
1
Check that the display data (Note4)
satisfies the R ratio specified value.
18
0
03
05
Set the data.
19
1
Check that the display data (Note4)
satisfies the B ratio specified value.
Note5:
The adjustment data will be automatically input to page: F, address:
2E, 2F.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
48
00
Set the data.
3
F
3E
Set the data that is written down
at step 4, and press PAUSE button.
4
F
3F
Set the data that is written down
at step 6, and press PAUSE button.
5
F
40
Set the data that is written down
at step 8, and press PAUSE button.
6
F
41
Set the data that is written down at
step 10, and press PAUSE button.
7
0
03
00
Set the data.
8
0
01
00
Set the data.
RadarW
RadarW
RadarW
Содержание DCR-TRV240
Страница 102: ...5 1 DCR TRV240 TRV340 SECTION 5 ADJUSTMENTS ...
Страница 177: ... Take a copy of OPTICAL AXIS FRAME with a clear sheet for use 206 OPTICAL AXIS FRAME DCR TRV240 TRV340 ...
Страница 179: ...DCR TRV240 TRV340 208 Sony EMCS Co 2002A1600 1 2002 1 Published by DI Customer Center 9 929 932 31 ...
Страница 180: ...Revision History Ver 1 0 Date 2002 01 History Official Release Contents S M Rev issued 992993231 pdf Reverse ...