5-23
9. MAX GAIN Adjustment
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
low illuminance will not be produced (dark).
Subject
Clear chart
(Color reproduction adjustment frame)
Adjustment Page
F
Adjustment Address
1D
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
96
00
Set the data.
3
6
97
1E
Set the data.
4
6
01
6F
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to “01”.
(Note)
Note:
The adjustment data will be automatically input to page: F, address:
1D
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
96
00
Set the data.
2
6
97
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
01
00
Set the data.
10. Auto White Balance & LV Standard Data Input
Adjust the white balance reference at 3200K, and adjust the normal
coefficient of the light value.
Subject
Clear chart
(Color reproduction adjustment frame)
Measurement Point
Display data of page 1 (Note4)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
1E, 1F, 30 to 33
Specified Value
0FE0 to 1020
Note1:
This adjustment should be carried out upon completion of “ Color
reproduction Adjustment”.
Note2:
After the power is turned on, this adjustment can be done only
once.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
LV data
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
11
Set the data, and press PAUSE
button.
3
6
01
0D
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to “01”.
(Note5)
5
F
10
2E
Set the data, and press PAUSE
button.
6
1
Check that the display data (Note4)
satisfies the specified value.
Note5:
The adjustment data will be automatically input to page: F, address:
1E, 1F, 30 to 33.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
F
10
00
Set the data, and press PAUSE
button.
3
0
01
00
Set the data.
4
Perform “Auto White Balance
Adjustment”.
RadarW
RadarW
RadarW
RadarW
RadarW
RadarW
RadarW
RadarW
RadarW
RadarW
Содержание DCR-TRV15E
Страница 89: ...DCR TRV15E TRV17E 4 57 DIGITAL STILL CONTROL MPEG MOVIE PROCESS MS 070 ...
Страница 95: ...DCR TRV15E TRV17E 4 69 4 70 USER FUNCTION CK 101 Uses unleaded solder ...
Страница 109: ...5 1 DCR TRV15E TRV17E SECTION 5 ADJUSTMENTS ...
Страница 183: ... Take a copy of OPTICAL AXIS FRAME with a clear sheet for use 220 OPTICAL AXIS FRAME ...
Страница 185: ...DCR TRV15E TRV17E 222 9 929 890 31 Sony EMCS Co Kohda TEC 2001G1600 1 2001 4 Published by PV Customer Center ...