“A” and “B” on the above list are defined as follows:
Command
Command list controllable with external devices
For the XX column without the comment “in decimal,” input the XX value in hexadecimal.
* The FREEZE command functions only for FM1.
Return command sent to an external device by the switcher
9
GND
Frame Ground
Pin No.
Signal
Function
B
R
T
A
A<B
t
“1” (MARK)
T: Transmit
R: Receive
A>B
t
“0” (SPACE)
Function
Protocol
XX
YY
CROSS
POINT
PGM
03 01 80 XX
01: Button 1
n: Button n
NEXT
03 01 81 XX
01: Button 1
n: Button n
TRANSITION M/E TRANS
MODE
03 01 90 01
M/E TRANS
TYPE
03 01 91 XX
02: Mix
04: Wipe
DSK TRANS
MODE
03 00 90 02
AUTO
TRANS
START (M/
E)
04 01 96 0X YY
third digit of the
frame number (in
decimal)
second and first
digits of the frame
number (in
decimal)
AUTO
TRANS
START
(DSK)
04 00 96 0X YY
third digit of the
frame number (in
decimal)
second and first
digits of the frame
number (in
decimal)
ALL STOP
M/E TRANS 03 01 97 01
DSK TRANS 03 00 97 02
DSK
DSK ON
03 00 DA 10
DSK OFF
03 00 9A 10
WIPE
WIPE
PATTERN
05 01 9B 00 0X
YY
third digit of the
number (in
decimal)
second and first
digits of the
number (in
decimal)
DIRECTION 04 01 9B 04 XX
02: Normal
04: Receive
FREEZE
*
FREEZE ON 03 14 80 00
SNAP SHOT RECALL
04 21 90 02 XX
00 to 63
Function
Protocol
ACK
84 (hexadecimal)
Содержание BRS-200
Страница 32: ...32 Processor Unit Chapter 2 Locations and Functions of Parts ...
Страница 62: ...62 Basic Setups for the Switcher Chapter 3 Preparations ...
Страница 100: ...100 Storing the Settings of a Wipe PIP and Setting Menu Items Chapter 4 Switching Operation ...
Страница 118: ...118 Setting the Illumination of the Tally Lamp on the Camera Chapter 5 VISCA Camera Operations ...
Страница 130: ...130 Transferring Data between the Switcher and a Computer Chapter 6 Control Using External Devices ...