137
Menu List
App
end
ix
To register the name of the signal (menu page 921)
Each of the signals input from the connectors on the Processor Unit and frame memories, color mattes
and color bars built in the switcher can be named in four characters to register.
Open the menu page 921 and follow the procedure below:
1
Turn the F1 or F2 control to select the signal to be registered.
2
Press the F2 control to highlight a character.
3
Turn the F2 control to change the highlighted character.
4
Turn the F3 control to move the highlighting to the character to be changed.
When you move the highlighting to the space next to the fourth character on the right, the input
characters are registered.
900 CAMERA.. 910 PWR MNG.. 917 CAM BTN
All
, 1 to 7
Sets power ON/OFF of the camera that
corresponds to the CAMERA button using
the F1 to F3 controls.
When AUTO ON is set to On, the power for
all the connected cameras is turned on in
conjunction with the switcher’s power.
TURN
Off
, On
APPLY
NOP
, Exec
AUTO ON Off,
On
PWRSTAT.. 918 CAM BTN
1
to 7
The power status of the camera that
corresponds to the CAMERA button is
displayed under STATUS when the F4
control is pressed.
NAME
(4-character indication)
STATUS
Sensing, On, Stand-By, Off,
Non Asgn (indication only)
CHECK
Exec
INPUT..
920 NAME..
921 SIGNAL
IN 1
, IN 2, IN 3, IN4, IN 5, IN 6,
IN 7, IN 8, IN 9, FM 1, FM 2,
MAT1, MAT2, CLBR
Allows you to register the name (in 4
characters) identifying each of the signals
input from the connectors on the Processor
Unit and frame memories, color mattes, and
color bars built in the switcher.
For details, see “To register the name of the
signal (menu page 921)” on page 137.
RENAME
(4-character definition to be
input)
<=>
ASSIGN..
922 XPT BTN
1
to 12
Assigns signals to the cross-point buttons.
Disables operation of the selected cross-
point button when INHIBIT is set to On.
SIGNAL
IN 1
, IN 2, IN 3, IN 4, IN 5, IN
6, IN 7, IN 8, IN 9, FM 1, FM 2,
MAT1, MAT2, CLBR
NAME
(4-character indication)
INHIBIT
Off
, On
ADJUST..
923 XPT BTN
1
to 12
Adjusts the levels of the signals that
correspond to the cross-point buttons.
Note
These adjustments are not available for DVI,
color matte, or frame memory signals.
Y-LEVEL
0.50 to 1.50 (
1.00
) (in 0.01)
SETUP
–10.0
to
10.0 (
0.0
) (in 0.5)
C-LEVEL
0.50 to 1.50 (
1.00
) (in 0.01)
PROC..
924 SIGNAL
IN 5
, IN 9
Sets the process of the aspect ratio of the
signal input from IN 5 or IN 9 when the
optional BRSA-20DD1 is installed.
For details, see “Conversion between Input
Signal and Output Signal” on page 142.
Note
These items can be set only when FORMAT
is set to HD on menu page 951.
NAME
(4-character indication)
4:3 PROC
WidZoom
, Center,
Zoom
FS..
925 SIGNAL
SDI1
, SDI2, SDI3, SDI4, SDI5,
SDI6, SDI7, SDI8
Allows you to add FS (frame synchronizer)
to the input signal selected under SIGNAL.
Set FS to On for the connected device to
which external sync signal cannot be added.
NAME
(4-character indication)
FS
Off,
On
SIDE..
926 LUM
0.0
to 100.0 (in 0.1)
Sets color matte for the side cut area for an
available signal.
The F1 to F3 controls and the joystick can
be used for the setting.
SAT
0.0
to 100.0 (in 0.1)
HUE
0.0 to 359.5 (in 0.5)
Setting menu
Setting item
Description
Содержание BRS-200
Страница 32: ...32 Processor Unit Chapter 2 Locations and Functions of Parts ...
Страница 62: ...62 Basic Setups for the Switcher Chapter 3 Preparations ...
Страница 100: ...100 Storing the Settings of a Wipe PIP and Setting Menu Items Chapter 4 Switching Operation ...
Страница 118: ...118 Setting the Illumination of the Tally Lamp on the Camera Chapter 5 VISCA Camera Operations ...
Страница 130: ...130 Transferring Data between the Switcher and a Computer Chapter 6 Control Using External Devices ...