46
SonicWall
SuperMassive
9800
Getting
Started
Guide
MAC
address.
This
simplifies
the
process
of
updating
network
ARP
tables
and
caches
when
a
failover
occurs.
Only
the
switches
that
the
two
appliances
are
directly
connected
to
needs
to
be
notified.
All
outside
devices
will
continue
to
route
to
the
single
shared
MAC
address.
This
option
is
not
selected
by
default.
Click
Apply
to
save
any
of
the
settings
on
this
page.
For
more
information
regarding
the
optional
settings,
see
the
SonicOS
Administration
Guide
.
Configuring
HA
Advanced
Settings
These
advanced
optional
settings
are
configured
on
the
High
Availability
>
Advanced
page.
When
finished,
click
Accept
to
retain
the
settings.
•
Adjust
the
Heartbeat
Interval
to
control
how
often
the
two
units
communicate.
The
default
and
recommended
minimum
is
1000
milliseconds;
the
minimum
is
1000
milliseconds
and
the
maximum
is
300000
milliseconds.
•
The
Failover
Trigger
Level
sets
the
number
of
heartbeats
that
can
be
missed
before
failing
over.
SonicWall
recommends
leaving
this
field
at
its
default
setting
of
5
,
and
adjusting
later
if
needed.
The
minimum
is
4,
and
the
maximum
is
99.
•
Set
the
Probe
Interval
for
the
interval
in
seconds
between
communication
with
upstream
or
downstream
systems.
The
recommended
setting
is
an
interval
of
at
least
20
seconds
(the
default).
The
minimum
is
5
seconds,
and
the
maximum
is
255
seconds.
You
set
the
Probe
IP
Address(es)
on
the
High
Availability
>
Monitoring
page.
•
Set
the
Probe
Count
,
which
is
the
number
of
consecutive
probes
before
the
appliance
considers
the
network
path
unreachable
or
broken.
The
default
count
is
3
;
the
minimum
is
3,
and
the
maximum
is
10.
•
The
Election
Delay
Time
is
the
number
of
seconds
allowed
for
internal
processing
between
the
two
units
in
the
HA
pair
before
one
of
them
takes
the
primary
role.
SonicWall
recommends
leaving
this
field
at
its
default
setting
of
3
seconds,
then
tuning
later
if
needed.
The
minimum
is
3,
and
the
maximum
is
255.
•
Enable
the
Active/Standby
Failover
only
when
ALL
aggregate
links
are
down
checkbox
to
treat
the
aggregated
link
as
down
(causing
a
failover)
only
if
all
member
links
are
down.
This
option
is
not
selected
by
default.
•
Select
the
Include
Certificates/Keys
checkbox
to
have
the
appliances
synchronize
all
certificates
and
keys.
This
option
is
selected
by
default.
Содержание SuperMassive 9800
Страница 1: ...SonicWall SuperMassive 9800 Getting Started Guide Regulatory Model Number 2RK04 0AD...
Страница 36: ...36 SonicWall SuperMassive 9800 Getting Started Guide...
Страница 58: ...58 SonicWall SuperMassive 9800 Getting Started Guide...
Страница 61: ...SonicWall SuperMassive 9800 Getting Started Guide 61 Mount Chassis Member Mount chassis with eight 8 M4 screws...
Страница 64: ...64 SonicWall SuperMassive 9800 Getting Started Guide...
Страница 72: ...72 SonicWall SuperMassive 9800 Getting Started Guide...
Страница 75: ...SonicWall SuperMassive 9800 Getting Started Guide 75...
Страница 76: ...SuperMassive 9800 Getting Started Guide Updated July 2017 232 003430 50 Rev A...