6
GB
Electrical connections for the various peripherals
Cut the electric power supply to the motor before performing any work on peripherals. If the display remains off after working on the system, check
the wiring (for possible short circuits or polarity reversals).
General electrical diagram (Fig. 29)
Photoelectric cells (Fig. 30)
Two types of connections can be made:
A:
Standard (without self test): program the setting “
P2
”
= 2
.
B:
With self test: program the setting “
P2
”
= 1
.
This means that an automatic test is conducted to check photoelectric cell operation every time the door operates.
If the test fails, no door movement is possible.
Reflex photoelectric cell (Fig. 31)
With self test: program the setting “
P2
”
= 1
.
This means that an automatic test is conducted to check photoelectric cell operation every time the door moves.
If the test fails, no door movement is possible.
Sensor bar (Fig. 32)
With self test: program the setting “
P2
”
= 1
.
This is used to perform an automatic test of sensor bar operation every time the door moves.
If the test result is negative, no door movement is possible.
Make sure you have correctly configured parameter “P2” taking into account the photoelectric cells or the sensor bar.
Orange light (Fig. 33)
Program the setting “
P1
” depending on the required operating mode:
. Without warning before door movement: “
P1
”
= 0
.
. With a 2 s warning before door movement: “
P1
”
= 1
.
Code keypad (Fig. 34)
Pedestrian door safety kit (Fig. 35)
When the pedestrian door contact is fitted, it must be connected in place of the jumper normally fitted between terminals 5 and 6 in the terminal
block.
If the pedestrian door contact is removed, the jumper between terminals 5 and 6 in the terminal block must be refitted.
Battery (Fig. 36)
Antenna (Fig. 37)
Remote lighting (Fig. 38)
Class 2 (double insulation) light units that are connected do not require an earth connection.
If a Class 1 (single insulation) light unit is used, always connect it to earth.
Figs. 29 to 38
CONNECTING PERIPHERALS
Key
Description
Key
Description
1
Orange light
6
Battery
2
Remote lighting
7
Pedestrian door safety kit
3
Code keypad
8
Photoelectric cells
4
Keyswitch
9
Reflex type cells
5
Antenna
10
Sensor bar
Description of the various peripherals Fig. 29
5048554A-GB 1/10/07 17:23 Page 6
Содержание Home motion Dexxo Pro io
Страница 11: ...11 GB somfy com 5048554A Dexxo Pro io User Manual 5048554A GB 1 10 07 17 24 Page 11 ...
Страница 30: ...12 ES NOTAS 5048554A ES 11 07 07 14 06 Page 12 ...
Страница 31: ...13 ES somfy com 5048554A Dexxo Pro io Manual de utilización 5048554A ES 11 07 07 14 06 Page 13 ...
Страница 50: ...12 PT NOTAS 5048554 PT 11 07 07 14 26 Page 12 ...
Страница 51: ...13 PT somfy com 5048554A Dexxo Pro io Manuel d utilisation 5048554 PT 11 07 07 14 26 Page 13 ...
Страница 70: ...12 GR ΣΗΜΕΙΩ ΩΣΕΙΣ 5048554A GR 2 10 07 9 05 Page 12 ...
Страница 71: ...13 GR somfy com 5048554A Dexxo Pro io Εγχειρίδιο χρήσης 5048554A GR 2 10 07 9 05 Page 13 ...