7
GB
SETUP
Setup general diagram
Meaning of the different settings
Fig. 39
Code
Description
Values
Comments
P0
Operating mode
0: sequential
1: automatic closure
Automatic closure mode operation is only possible if photoelectric cells are
fitted, i.e. P2=1 or P2=2.
In automatic closure mode, the door is automatically closed after the end of
the time delay set with setting “
t0
”.
P1
Orange warning light
0: without advance warning
1: with 2 s advance warning
If the garage opens onto a public road, always select with advance
warning: P1=1.
P2
Safety input
0: no safety mechanism
1: safety mechanism with self test
2: safety mechanism without self test
If value 0 is selected, the safety input is not taken into account.
If value 1 is selected, the system’s self test is run at the start of every
operating cycle.If value 2 is selected, the safety system runs without a self
test: it is essential to test its proper operation every six months.
P3
Obstacle detection
sensitivity
0: very low sensitivity
1: low sensitivity
2: standard
3: high sensitivity
If this setting is changed, it is essential to run the force measurement
sequence at the end of the installation procedure (refer to the Installation
Checklist for domestic doors in residential areas) or install a sensor bar.
P4
Partial opening cycle
0: not valid
1: valid
If the partial opening cycle is validated:
. A short press on the remote control button will partially open the door,
. A long press on the remote control button will fully open the door.
P5
Closing speed
0: fast
1: standard
2: slow
If this setting is changed, it is essential to run the force measurement
sequence at the end of the installation procedure (refer to the Installation
Checklist for domestic doors in residential areas) or install a sensor bar.
P6
Partially open position
Storing the position as illustrated in
Fig. 41.
P7
Closure approach speed
0: standard
1: short soft stop
2: long soft stop
P7=0: the door does not slow before closure.
P7=1: the door speed slows 20 centimetres before closure.
P7=2: the door speed slows 50 centimetres before closure.
A0
Safety action prior to
opening (safety ADMAP)
0: no effect
1: movement rejected
If value 1 is selected, triggering the safety input will inhibit door opening.
A1
Safety action during closure
1: stop
2: partially reopen
3: fully reopen
Value 1 is not allowed when using a sensor bar on the safety input.
A2
Obstacle detection action
during closure
2: stop + partially open position
3: fully reopen
t0
Automatic closure time
delay
0 to 12 (time delay value = value x 10 s)
e.g.
2
2 =
= 2
20
0 ss
t1
Lighting time delay
0 to 60 (time delay value = value x 10 s)
e.g.
6
6 =
= 6
60
0 ss
Remark: Due to the thermal cut out protection system, the integrated light
may cut out automatically if it is used for an extended length of time. We
therefore recommend selecting a light time delay in excess of 2 mn
(t1=12 or 120s) only when remote lighting is used.
(Boldface text = default values)
5048554A-GB 1/10/07 17:23 Page 7
Содержание Home motion Dexxo Pro io
Страница 11: ...11 GB somfy com 5048554A Dexxo Pro io User Manual 5048554A GB 1 10 07 17 24 Page 11 ...
Страница 30: ...12 ES NOTAS 5048554A ES 11 07 07 14 06 Page 12 ...
Страница 31: ...13 ES somfy com 5048554A Dexxo Pro io Manual de utilización 5048554A ES 11 07 07 14 06 Page 13 ...
Страница 50: ...12 PT NOTAS 5048554 PT 11 07 07 14 26 Page 12 ...
Страница 51: ...13 PT somfy com 5048554A Dexxo Pro io Manuel d utilisation 5048554 PT 11 07 07 14 26 Page 13 ...
Страница 70: ...12 GR ΣΗΜΕΙΩ ΩΣΕΙΣ 5048554A GR 2 10 07 9 05 Page 12 ...
Страница 71: ...13 GR somfy com 5048554A Dexxo Pro io Εγχειρίδιο χρήσης 5048554A GR 2 10 07 9 05 Page 13 ...