9
GB
Code
Description
Comments
Action required?
E1
Maximum force reached
During learning, the door requires too much force
for the motor.
Check door balance and correct operation by
manual operation.
E4
Safety mechanism self test fault
The safety device self test failed.
Check that “
P2
” is setup correctly depending on
the devices connected to the safety input.
Check safety device wiring.
When photoelectric cells are used, check their
proper alignment.
E9
Thermal cut out
Indicates that the motor has reached its
maximum operating temperature after a number
of continuous cycles.
Wait until the motor returns to its normal
operating temperature.
Eb
Other faults and failure conditions
These codes correspond to various electronic
circuit board failures.
Cut the power supply (mains & battery back-up),
wait for a few minutes then re-connect the power
supply.
Perform a learning cycle.
If the fault persists, contact Somfy Technical
Support.
Error and failure codes displayed
Programming codes displayed
Code
Description
Comments
S0
Awaiting setting:
Motor operating direction for swinging doors
Pressing the “
+
” or “
-
” buttons on the keypad will move to S1.
Pressing the “
SET
” button for 2 s starts the learning mode.
S1
Awaiting setting:
Motor operating direction for up and over or
sectional doors
Pressing the “
+
” or “
-
” buttons on the keypad will move to S0.
Pressing the “
SET
” button for 2 s starts the learning mode.
S2
Learning mode
Pressing the “
OK
” button starts the learning cycle: the S2 display blinks during the entire cycle.
Pressing the “
+
” or “
-
” buttons will control the motor in forced mode.
F0
Awaiting motor control memorisation
Pressing a remote control button will assign this button to motor control.
Pressing the “
PROG
” button will call up the “Awaiting remote lighting control memorisation mode:
F1
”.
TROUBLESHOOTING
Operating codes displayed
CCo
od
dee
Description
Comments
C1
Waiting for a command
C2
Door opening
C3
Waiting for the door to close
C4
Door closing
C5
Obstacle detection
Displayed during obstacle detection then for 30 s.
C6
Safety input active
Displayed after a movement request or during movement, when the safety input is active.
This display is maintained as long as the safety input is active.
C9
Pedestrian door safety contact active
Displayed after a movement request or during movement, when the pedestrian door contact is open.
The display is maintained as long as the pedestrian door contact remains open.
Ca
Safety mechanism self test
Displayed during safety mechanism self tests.
Cd
Working from back-up battery
Waiting for a command
5048554A-GB 1/10/07 17:23 Page 9
Содержание Home motion Dexxo Pro io
Страница 11: ...11 GB somfy com 5048554A Dexxo Pro io User Manual 5048554A GB 1 10 07 17 24 Page 11 ...
Страница 30: ...12 ES NOTAS 5048554A ES 11 07 07 14 06 Page 12 ...
Страница 31: ...13 ES somfy com 5048554A Dexxo Pro io Manual de utilización 5048554A ES 11 07 07 14 06 Page 13 ...
Страница 50: ...12 PT NOTAS 5048554 PT 11 07 07 14 26 Page 12 ...
Страница 51: ...13 PT somfy com 5048554A Dexxo Pro io Manuel d utilisation 5048554 PT 11 07 07 14 26 Page 13 ...
Страница 70: ...12 GR ΣΗΜΕΙΩ ΩΣΕΙΣ 5048554A GR 2 10 07 9 05 Page 12 ...
Страница 71: ...13 GR somfy com 5048554A Dexxo Pro io Εγχειρίδιο χρήσης 5048554A GR 2 10 07 9 05 Page 13 ...