background image

Operating Manual

Sliding Door Drive Engine

V

EN

Summary of Contents for s4000

Page 1: ...Operating Manual Sliding Door Drive Engine V EN ...

Page 2: ...2 1 with terminal plug in terminal 50 53 6 5 2 2 with notebook plug in terminal 1 3 6 5 3 Fault clearance during putting into operation procedure 6 6 0 Features______________________________________________________________________7 6 1 Standard feature 7 6 2 Optional Features 7 6 3 Safety features 7 7 0 Maintenance Safety check______________________________________________________8 8 1 Error code ...

Page 3: ...k for people and the system in case of inappropriate handling TIPS INFORMATION Useful hints and tips you should pay particular attention to 1 3 Instruction The professional use and the risks in case of improper use must be pointed out to permanent users of a door system The appropriate operating instructions serve as an aid 1 Electrical terminal strip 5 Electrical terminal strip 2 Motor control un...

Page 4: ... of the selected parameters func tions P Three functions can be activated 1 To switch from main level to parameter level and vice versa 2 Abort at parameter or PS level 3 Position change in password or date time input and have two functions 1 Selection of the parameter number or the parameter value 2 Selection of the PS function 2 9 4 Parameter settings The parameters are factory preset according ...

Page 5: ...meter 61 select 1 Display PS mode Use the or key to select the desired mode here Closing time Use the E key to accept this mode Display PS mode active blue LED Closing time 2 9 6 Technical data Voltage Supply 100 VAC 240 VAC 50Hz 60Hz Protection class IP 00 Suitable only in dry locations Power supply for external equipment 24 V DC max 1 A total input current Power consumption max 210 W Power consu...

Page 6: ...bly 5 0 Putting into operation The setting up of the driving mechanism for the putting into operation procedure described below must be re peated after each technical modification 5 1 Precondition The specifications in the operating instructions of the driving mechanism must be observed Assembly work at the door and the driving mechanism must have been finished and the height and the side clearanc...

Page 7: ... door closes according to the preset stand open time Magnetic break MB 44 45 For special uses e g naval architecture Potential equalisation Potential equalisation by sliding contact Other optional connections Code keyboard remote control non contact push button terminal notebook PC fault detector identification etc 6 3 Safety features Electronic reversion In both motion directions the reversing fo...

Page 8: ...beyond the set value range error messages are displayed The error is indicated at the terminal in plain text and as a colour code on the LEDs installed at the driving unit at the same height as the connector strip 8 1 Error code Trouble Shooting Colour code Error display Possible cause Fault clearance Reset Defective motor Defective motor electronics Replacement of driving unit by Service Perso ne...

Page 9: ...ock time 1 end closing time Lock time 1 end closing time hh mm ss 17 Running in OPEN Running in zone OPEN 10 200 mm 40 72 Lock time 2 start closing time Lock time 2 start closing time hh mm ss 18 Running in CLOSE Running in zone CLOSE 10 200 mm 50 73 Lock time 2 end closing time Lock time 2 end closing time hh mm ss 19 Safe distance Safe distance 0 30 mm 10 74 Lock time 3 start closing time Lock t...

Page 10: ...onds for motion sensor Inside Parameter 4 Stand open time in seconds for motion sensor Outside Parameter 5 Stand open time in seconds after reversing Parameter 6 Stand open time in seconds for complete opening 2 Parameter 7 Delay time until activation of electrical lock Parameter 8 Automatic start 0 door starts after key actuation 1 door starts automatically Parameter 9 Password protection of term...

Page 11: ...eter 34 The braking slope OPEN ensures a fast slowing down of the door in OPEN direction without any jerks The works setting of the parameter value is 400 It should only be modified with care Smaller values signify a steeper slope i e the door is slowed down faster greater values signify a more gentle slope i e the door is slowed down less fast Attention This parameter affects the service life of ...

Page 12: ... normal mode 1 closing time mode motion sensor Outside is deactivated Parameter 57 Automatic electrical lock 0 deactivated 1 active Parameter 58 Interlock K1 as NO contact 0 or NC contact 1 K1 is activated at each opening of the door Parameter 59 1 after reversing door remains in open position until time parameter 5 has elapsed 0 after reversing door remains in open position until a key is pressed...

Page 13: ... manually operated The door is opened by motor operation The PartlyOpen function is carried out 3 door can be manually operated The door is opened by motor operation The PermanentlyOpen function is carried out 4 door can be manually operated The door opens automatically until the set opening width para meter 15 is reached The PermanentlyPartlyOpen function is carried out Parameter 84 Safety elemen...

Page 14: ...ngs must be entered Enter connection name and select icon Select serial port Note If you are using the USB to Serial adapter cable you have to choose the emulated port Enter connection settings Select font and size Other Settings Complete data connection Plug in data cable terminal 1 3 and connect it to the PC Notebook 9 pole D Sub plug to the serial interface RS 232 If you quit the terminal appli...

Page 15: ...1 P95 Page 2 Automatic door S 4000 L ETyp 123 5 Reisinger GmbH c 2008 V 1 10 S N 0751001 MTyp SK 41 Date 14 03 08 61 Program switch 0 42 Time 09 38 22 62 Factory setting 43 daylight summer time 0 63 LED frame 1 44 64 Output AUX 1 45 65 Acoustic signals 1 46 66 automatic open 0 47 67 48 68 49 69 50 Reference drive 70 Lock time 1 begin 00 00 00 51 Special function 6 71 Lock time 1 end 00 00 00 52 Re...

Page 16: ...11 0 Terminal connection diagrams 11 1 Wiring diagram maximum total cable length 10m 16 ...

Page 17: ...11 2 Terminal assignment V EN 17 ...

Page 18: ...12 0 Dimensions 12 1 Sectional drawing one wing drive 18 ...

Page 19: ...12 2 Sectional drawing telescopic and two wing drive V EN 19 ...

Page 20: ...Reisinger GmbH 3HWWHQVLHGHOHU 6WU FNHQWDO 7HO D www reisinger de info reisinger de Your qualified REISINGER Partner 20 ...

Reviews: