7
Input / Output Ports
There are 8 digital input ports, 1 analog input port and 8 digital output ports in the CIE-M10.
User should make hardware interfaces to the CIE-m10 for user own purpose.
Those input and output ports are monitored or controlled three ways – Modbus/TCP, Macro,
and HTTP.
Method
Description
Modbus/TCP
Modbus/TCP protocol is used to communicate with CIE-M10‟s I/O ports.
When CIE-M10 is in Slave/Passive mode, it operates as a standard
Modbus/TCP device. It can be operated as a master. A master outputs
data after reading remote device‟s input ports and write to the remote
device‟s output ports after reading its input ports. It can also establish
TCP active connection.
Macro
It is a mode that allows the users automatically controls output port‟s
value based on input port status by setting Macro values prior to CIE-
M10 operation.
During Macro operation, current status values may be read using HTTP
or Modbus/TCP, but output values cannot be controlled.
HTTP
CIE-M10 can be controlled and monitored using web browsers.
Connect to CIE-M10‟s IP address via web browser to access CIE-M10‟s
control and monitor web page. This webpage shows current status
values.
User can upload user‟s own web pages into the CIE-M10 as well.
Table 7-1 Controlling the I/O port