IMPORTANT
ELECTRICAL INSTRUCTIONS
WARNING!
NEVER
use a ground fault circuit interrupt (GFCI) wall outlet with this treadmill. As
with any appliance with a large motor, the GFCI will trip often. Route the power cord
away from any moving part of the treadmill including the elevation mechanism and
transport wheels.
NEVER
remove any cover without first disconnecting AC power.
If voltage varies by ten percent (10%) or more, the performance of your treadmill may
be affected. Such conditions are not covered under your warranty. If you suspect the
voltage is low, contact your local power company or a licensed electrician for proper
testing.
NEVER
expose this treadmill to rain or moisture. This product is NOT designed for use
outdoors, near a pool or spa, or in any other high humidity environment. The maximum
operating temperature specification is 40 degrees c, and humidity is
90%
non-condensing(no water drops forming on surfaces).
Circuit Breakers
: Some circuit breakers used in exercise facilities or homes are not
rated for high inrush currents that can occur when a treadmill is first turned on or even
during use. If your treadmill is tripping the facility or home circuit breaker (even though it
is the proper current rating) but the circuit breaker on the treadmill itself does not trip, you
will need to replace the facility or home breaker with a high inrush type. This is not a
warranty defect. This is a condition we as a manufacture have no ability to control. This
part is available through most electrical supply stores. Examples: Grainger part # 1D237,
or available online at
www.squared.com
part # QO120HM.
GROUNDING
INSTRUCTIONS
This product must be grounded.
If the treadmill should malfunction or breakdown,
ground-ing provides a path of least resistance for electric current, reducing the risk of
electric shock. This product is equipped with a cord having an equipment-grounding
plug. The plug must be plugged into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
DANGER - Improper connection of the equipment-grounding conductor can result
in a risk of electric shock. Check with a qualified electrician or serviceman if you are
in doubt as to whether the product is properly grounded. Do not modify the plug
provided with the product if it will not fit the outlet; have a proper outlet installed by
a qualified electrician.
This product is for use on a nominal 110-volt circuit, and has a
grounding plug that looks like the plug illustrated below. A temporary adapter that looks
like the adapter illustrated below may be used to connect this plug to a 2-pole
receptacle as shown below if a properly grounded outlet is not available. The temporary
adapter should be used only until a properly grounded outlet, (shown below) can be
installed by a qualified
electrician. The green
colored rigid ear- lug, or the
like, extending
from the adapter, must be
connected to a permanent
ground such as a properly
grounded outlet box cover.
Whenever the adapter
is used, it must be held
in place by a metal
screw.