Setting
Setting
The “
Auto Restart” is used for restarting
output power manually
EPS System
EPS System
or automatically.
When the battery capacity reaches minimum capacity or battery voltage reaches
discharge cut voltage in EPS mode, the battery will stop discharging and the inverter will
stop exporting power from EPS port with showing “BAT power low” on the LCD display.
- Choosing “OFF” means the EPS System output power can only be restarted by
pressing the ESC button manually and the “OFF” is the default setting.
- Choosing “ON” means the EPS System output power can be restarted automatically
through setting the “Min ESC Soc”.
For example, if the user chooses “enable” and sets “Min ESC Soc” to 20%, it means the PV
will charge the battery. When the battery capacity reachs 20%, inverter will restart EPS
System output power and” BAT Power low” will disappear.
(1) EPS Auto Restart
> Func Select
ON
EPS Auto Restart
Reset
Reset Inv Energy
Reset Meter Energy
Factory Reset
Reset Errorlog
Cofig Guide
c-4.3) Reset
Each option can be set as YES or NO.
Reset Inv Energy :
User can reset the inverter energy record here.
> Reset
No
Reset Inv Energy
Reset Errorlog :
User can reset all inverter errorlog record here.
> Reset
No
Reset Errorlog
Reset Meter Energy :
User can reset the meter energy record here.
> Reset
No
Reset Meter Energy
Factory Reset :
User can reset the inverter manager parameter records here.
> Factory Reset
Factory Reset
Con g Guide:
This display will trigger the initial setting guide to re-play again.
c-4.4) New Password
Users can set a new password. The default password is “2018".
>
2 0 1 8
New Password
>Start
New Password
c-4.5) Function Type
Users can set the type of inverter, Hybrid or AC Coupled. This option can only be set
if the inverter is
.
A1 Hybrid
If choose the AC Coupled, then have to restart the inverter, this function will take
effect. And if you re-select the Hybrid, you will also have to restart the inverter.
Type
>AC Coupled <
Function Type
68