DANGER!
Fatal electric shock hazard!
After the inverter has been disconnected, high residual voltages remain in the
inverter for approx. 5 minutes.
■
■
Wait for 5 minutes.
5. Open the inverter as described in Section 5.1.
6. Use a suitable charge indicator to check that all terminals are free from voltage.
– When all terminals are de-energized, you can remove the AC feed cable, the 2nd
protective conductor and all communication lines from the inverter.
CAUTION!
Risk of burns due to hot casing components!
■
■
Wait until the back of the casing has cooled down.
7. Fit the contact protection.
8. Fit the cover of the inverter.
9. Remove the 2 lateral Phillips head screws that secure the inverter on the mounting
rail.
10. Disengage the inverter from the mounting rail.
103 Disposing of the inverter
Dispose of the inverter as indicated by the local waste disposal regulations. You can also
return the inverter, at your own cost, to Sputnik Engineering AG for professional disposal.
The contact details of the SolarMax Service Center can be found on the back of this