2 Safety information
2 Safety information
–
Keep unauthorised personnel away: Risk of burns
from hot pipes and components. Do not leave child-
ren unsupervised and check that they cannot
access the boiler.
–
If the electrical insulation on cables, plugs, swit-
ches becomes damaged, switch off the voltage
supply and have the insulation repaired. Protect
live parts against moisture.
–
If visible damage is found (e.g. leakage of water,
thermal deformation, traces of flue gas or
scorching, mechanical damage, etc.), operation
must not be continued or the boiler started up
again. The system may only be operated if it is in
perfect technical condition.
–
If the heating system is out of use for lengthy peri-
ods, it must be ensured that all parts carrying water
are fully protected against frost.
–
Never decommission safety devices; should they
fail, have them repaired immediately.
3 Efficient and low-emission ope-
ration
Recommendation of the EU energy effi-
ciency directive
Use of a buffer tank
Since maximum combustion is possible only in stan-
dard operation of the boiler, and greater losses and hig-
her emissions occur during the warm-up and burn-out
phases, use of a buffer tank is recommended.
This tank stores the water heated by the boiler, allo-
wing the connected devices (e.g. heating circuit, DHW
tank, fresh water module, etc.) to access it as requi-
red. This ensures sufficiently long, uninterrupted com-
bustion periods for the boiler.
Use of high-efficiency heating pumps
When using external heating pumps (e.g. return tem-
perature rise, heating circuit pumps, etc.), high-effi-
ciency pumps with energy efficiency class A should
preferably be used.
This delivers savings potential of up to 80 % in drive
energy (compared to conventional heating pumps) with
identical feed results.
4 Product information
4.1 Proper use
n
The heating boiler is intended for heating up water
in closed heating systems.
n
Use only fuel pursuant to the following spe-
cifications.
4.2 Fuel
Logs
n
Length of logs <50 cm, Ø <6 cm; otherwise, split.
n
Moisture content of the wood: < 25 %.
n
Bark proportion: < 20% (related to the total fuel
quantity).
n
Ash content: < 2 % (related to the total fuel quan-
tity).
4.3 Product description
The thermi
nator
-II is a heating boiler for the combustion
(gasifier technology) of log wood. The boiler has an
automatic fuel ignition system (optional) and automatic
cleaning of the heat exchanger surfaces.
4.4 Spare parts
Use only original spare parts from the manufacturer.
The manufacturer cannot accept any liability for
damage caused by spare parts not supplied by the
manufacturer.
4.5 Accessories
4.5.1 Automatic ignition
n
Hot air fan for automatic ignition of the fuel.
n
Is installed on the left side of the boiler (also sui-
table for retrofitting in existing boilers).
4
Operation manual
therminator II touch