![SOLARFOCUS Therminator II Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/solarfocus/therminator-ii/therminator-ii_operation-manual_1313815019.webp)
6 Operating mode Logs
6.4
Glow holding
function
i
Function must be activated by qualified per-
sonnel.
The log wood located in the filling chamber has not
been fully combusted. The embers or charcoal that
remain in this way can easily be re-ignited (manually or
automatically by the hut air blower).
Figure: Unburned, charred log residue after burning
with glow holding.
n
The time to wait between switching off glow hol-
ding and repeated ignition is unimportant. What is
important for straightforward ignition is the pre-
sence of the charred log wood residue.
n
Each time the heat-up process is performed, you
will be asked whether you would like to start burn-
off with or without glow holding.
Fig. 2-22_01-100
Manual ignition after combustion with
Glow hol-
ding
►
Push the charred pieces together on the stainless
steel combustion grate using the poker.
►
In the boiler control, select the
Log wood
operating
mode and press the
Start
button.
►
Ignite a sheet of paper and let it fall, burning, into
the filling chamber (the flame is sufficient to ignite
the rest of the material).
►
Wait for a moment until the rest of the material is
visibly burning.
►
As described above, add more log wood and close
the filling chamber door.
Operation manual
therminator II touch
19