![SOLARFOCUS Therminator II Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/solarfocus/therminator-ii/therminator-ii_operation-manual_1313815020.webp)
7 Operating mode Logs automatic
7 Operating mode
Logs auto-
matic
Description of operating mode
n
This is an optional additional function.
n
The log wood stacked in the boiler filling chamber
is ignited using the automatic ignition device (hot
air fan).
n
Note: The function
Glow holding
function simplifies
the next ignition process.
i
Recommendation for your first (three to four)
ignition attempts with the automatic log wood
function: Only fill the boiler filling chamber with
log wood once ignition has been performed suc-
cessfully. This means that you will not have
clear out all of the filled material if you have a
failed attempt at ignition.
7.1 Preparations for the operating type.
see
6.1 Preparations for the operating type.
7.2 Stack the log wood in the filling cham-
ber
►
IMPORTANT: Before filling with log wood, place
slightly flammable material (balled up paper, card-
board or similar) on the stainless steel combustion
grate, directly before igniting
1
the hot air fan.
►
Fill the boiler with fuel in the following sequence:
–
Dry, slightly flammable material in small pieces
–
Split logs, medium-sized
–
Split logs, large
see also
6.2 Stack the log wood in the filling cham-
►
After filling the boiler, close the filling chamber
door.
Select operating mode and start
►
After filling the boiler: Select the
Log wood
ope-
rating mode and press the
Start
button.
Fig. 2-23_01-164_06sn
Ä
The ID fan and and hot air fan start when a
time release is available
and, if a
heating request is issued to the boiler.
i
Starting the boiler in
automatic log wood func-
tion
mode is possible only in the status
Burner
switched off or
Log burning is terminated
.
7.3 Replenish with logs
see
7.4 Glow holding function
see
Automatic ignite (with hot air fan) after com-
bustion with
glow holding
►
Push the charred pieces together on the stainless
steel combustion grate using the poker.
►
Fill the boiler with log wood as usual, i.e. in layers
of different fuel; see detailed description
►
In the boiler control, select the
Automatic log
wood function
operating mode and press the
Start
button.
20
Operation manual
therminator II touch