16 Filling the pellet storage area
Possible messages
The message in question determines who is sup-
posed to take the required action (system operator
SO
or qualified personnel
QP
).
No. Message
SO QP
1 Internal memory is invalid
x
2 Feeder sensor short circuit
x
3 Filling level sensor may be dusty
x
5 Flue gas temperature too low
x
6 Flue gas sensor disruption
x
7 Flue gas sensor wrong measured value
x
8 Feeder sensor disruption
x
9 Flue gas sensor short circuit
x
10 Factory settings loaded
x
11 Error rotational speed feedback
x
12 Rotational speed feedback test
x
13 Rotational speed feedback Not OK
x
14 Maximum suction run time reached
x
15 Error feed sensor measured value
x
16 Error lambda sensor measurement
x
17 Error boiler temperature sensor
x
19 Extraction auger is blocked
x
x
20 First ignition attempt was unsuccessful
x
21 Defective Triac feed screw
x
23 Communication with module interrupted
x
24 Safety chain has triggered
x
25 A power failure has occurred
x
26 Mains fuse F3 defective
x
27 Triac fuse F6 defective
x
30 Feed blockage
x
31 Heat exchanger is blocked
x
32 Heat exchanger is blocked
x
33 No feed motor current flow
x
35 CAN bus interruption
x
36 Fuse at fresh water module defective
x
37 A fuse in the electronic module (solar
module) is defective
x
38 Commissioning settings have been loa-
ded
x
40 Pellet ignition fault/pellet shortage?
x
x
41 FUSE F1 or F8 defective
x
42 Shortage of pellets in storage area
x
43 Fault in diverter for suction heads
x
44 Communication error cascade
x
46 The ash container is full and must be
emptied
x
47 Heating boiler maintenance recom-
mended!
x
49 Boiler door or ash container is open
x
No. Message
SO QP
50 The boiler door is open!
x
51 Battery in operating element (display) is
dead
x
52 Limiting thermostat is open
x
x
67 Indoor air damper does not open
x
68 Indoor air damper does not close
x
69 Error communicating with the indoor air
module
x
71 No current flow heat exchanger
x
72 Note: No current flow heat exchanger
x
73 Fault in reference switch, diverter
x
74 Differential pressure switch has trig-
gered
(only possible with pellet
elegance
with com-
bustion grate)
x
75 Room temperature sensor assignment
x
76 Overtemperature reset triggered
x
77 Fuse F12 defective
x
78 Automatic ash extraction blockage
x
79 No current flow automatic ash extraction
x
1 - Internal memory is invalid
An error has occurred in the memory of the boiler con-
trol.
►
Check whether the customer/system-specific set-
tings are present in the boiler control.
2 - Feeder sensor short circuit
The temperature sensor of the pellet auger has short-
circuited and must be replaced.
3 - Filling level sensor may be dusty
►
Open the inspection cover on the intermediate
pellet store. Check whether there are any pellets
in front of the sensor. If there are no pellets pre-
sent, then the green LED should not light up. If it
does, wipe the sensor. If there is no change,
replace the sensor.
5 - Flue gas temperature too low
The time limit for reaching the calculated flue gas
required temperature has been exceeded.
►
Clean the stainless steel combustion grate, com-
bustion chamber and flue gas pipe
6 - Flue gas sensor disruption
The flue gas temperature sensor has a fault and must
be replaced.