7 DHW heating
Current
outside tem-
perature
Perceived
room tem-
perature
Recommended adjust-
ment of heating curve
-5°C to +5°C
too cold
Increase temperature
value at
7
and
8
too hot
Reduce temperature
value at
7
and
8
+5°C to
+15°C
too cold
Increase temperature
value at
8
too hot
Reduce temperature
value at
8
3-point heating curve
i
Function must be activated by qualified per-
sonnel.
Depending on the standard of building and insulation,
it is advisable to change over from the 2-point to a 3-
point heating curve. In contrast to the 2-point heating
curve, it is possible to stipulate a third temperature
11
, i.e. the heating curve can include a sharp deflec-
tion or bend.
Abb. 2-30
Adjustment of the 3-point heating curve (in
hea-
ting mode
)
i
Note the currently set temperatures before
you change the values.
Current
outside tem-
perature
Perceived
room tem-
perature
Recommended adjust-
ment of heating curve
-15°C to -
5°C
too cold
Increase temperature
value at
7
too hot
Reduce temperature
value at
7
-5°C to +5°C
too cold
Increase temperature
value at
11
too hot
Reduce temperature
value at
11
+5°C to
+15°C
too cold
Increase temperature
value at
8
too hot
Reduce temperature
value at
8
7 DHW heating
DHW can be heated up in two ways:
–
With a
DHW tank
(the energy source of the DHW tank is the heating
boiler or a buffer tank
[1]
)
–
With a
fresh water module
(The energy source of the fresh water module is a
buffer tank
[1]
)
i
[1]
DHW area in the buffer tank
Warm water rises and collects in the upper-
most area ofthe buffer tank (= thermal stra-
tification). The DHW tank or the fresh water
module draws the required energy for DHW
heating from this uppermost area. Therefore,
this (held at an adjustable temperature level)
area in the buffer tank is also referred to as the
DHW area
.
7.1 Domestic hot water tank
Abb. 2-31
1 DHW tank temperature
2 Required DHW tank temperature
3 Temperature of the energy source (boiler, buf-
fer tank)
4 Info line: Charging requirement (Yes/No) to
the energy source.
5 DHW tank operating mode
6 DHW tank settings
7 DHW tank status line
Operation manual
pelletelegance
23