5 Use and operation
Change the VNC password
Abb. 2-20
►
Press the
Change VNC password
button on the
IP setup
view.
►
To change it, first enter the old password, then
the new password, then press the
Adopt
button.
►
The new password must be used to log on after
restarting the VNC Viewer on the local PC.
►
Press the
Reset password
button to reset the
password to the default password
solarfocus
.
Version 2: VNC viewer for access from an exter-
nal PC (PC outside the home network)
–
The user's local router does not always have the
same IP address on the Internet (it is allocated by
an
Internet Service Provider – ISP
).
–
Nevertheless, Dynamic Domain Name Systems,
also referred to as
DynDNS
or
DDNS
, allows
access to the router.
–
These systems allow a unique host name to be
assigned on the Internet; the unique name is then
also entered in the router. If the router is then assi-
gned a different address by the ISP, it enters the
updated IP address as the defined host name on
the DynDNS server. The router and therefore the
home network can then be reached using this
host name.
–
To create a connection with the control, a
port
diversion
is required from the external port of the
router
[1]
to the IP address and to VNC port 5900
of the control.
[1] Port 5921 is recommended
i
Avoid
any
port forwarding
from external port
5900 of the router to IP address and VNC port
5900 of the control.
5.4.6.3 Sending emails
Function: The boiler control
eco
manager-
touch
auto-
matically sends status emails and alarm e-mails (to
stored addresses) if required.
Status email
: An automatic email (e.g. sent daily) pro-
vides information on the current boiler status.
Alarm email
: a message is sent when a fault occurs.
i
Installation and configuration of this function
must be performed by the customer (i.e. not
included in the commissioning, service and
support activities).
Abb. 2-21
Outgoing mail server
1
Enter the access data for the e-mail server you use.
Abb. 2-22
Use SSL
: Select if the e-mail server uses a TLS/SSL
encryption protocol.
Address book
2
A maximum of 10 contacts can be added. If there are
several addresses for a contact, these should be
comma-separated.
18