Sokkia iX-1001 Скачать руководство пользователя страница 129

125

19. CHANGING THE SETTINGS

It is possible to allocate the Operating icons in Observation mode to suit the measurement conditions. It is 
possible to operate the instrument efficiently because unique Operating icon allocations can be preset to suit 
various applications and the ways that different operators handle the instrument.

• The current Operating icon allocations are retained until they are revised again, even when the instrument is 

powered OFF.

• Press

 [CLEAR]

 in <Customize/Select screen> in "19.12 Allocating Operating Icons" " PROCEDURE 

Allocating a Operating icon" step 2 to return all customized configurations including Status icon/starkey mode 
settings, and screen controls to their previous settings.

• When Operating icon allocations are recorded and registered, the previously recorded key settings are 

cleared. 

• Operating icons cannot be allocated to "Graphic" displays.

Screens that can be customized and Operating icon allocations when shipped

1. "SHV" and "SHVdist" displays of <Basic observation>

[TRK On] [MOTOR] [0SET] [MEAS]
[SRCH] [EDM] [H-SET] [COORD]
[OFFSET] [RESEC] [REM] [S-O]

2. "Obs." display of <Setting out>

[TRK On] [SHVR] [H.TURN] [MEAS]
[CNFG] [ --- ] [ --- ][REM]
[ --- ] [ --- ] [ --- ] [ --- ]

3. "SHV" and "NEZ" displays of <Set out Coords>

[OK] [TRK On][H.TURN] [MEAS]
[CNFG] [ --- ] [ --- ] [ --- ]
[ --- ] [ --- ] [ --- ] [ --- ]

Functions that can be allocated to the Operating icons
[ --- ]

: No functions set

[MEAS]

:  Distance and angle measurement

[0SET]

:  Set horizontal angle to 0°

[H-SET]

:  Set required horizontal angle

[SHV]

:  Switch the "SHV" display and "SHVdist" display (can only be allocated to 1 above)

[L/R]

:  Select horizontal angle left/right. The capitalized letter in the Operating icon indicates 

the currently selected mode.

[ZA / %]

:  Switch between zenith angle/slope in %. The capitalized letter in the Operating icon 

indicates the currently selected mode.

[HOLD]

:  Hold horizontal angle/release horizontal angle

[CALL]

:  Display final measurement data

[HVOUT-S]

:  Output angle measurement results to an external device (SET format)

[HVDOUT-S]

:  Output distance and angle measurement results to an external device (SET format)

[NEZOUT-S]

:  Output coordinates data to an external device (SET format)

[HVOUT-T]

:  Output angle measurement results to an external device (GTS format) (can only be 

allocated to 1 above)

[HVDOUT-T]

:  Output distance and angle measurement results to an external device (GTS format) 

(can only be allocated to 1 above)

[NEZOUT-T]

:  Output coordinates data to an external device (GTS format) (can only be allocated to 1 

above)

[F/M]

: Switch distance units between meters/feet

[HT]

:  Set the instrument station, coordinates and instrument height

19.12 Allocating Operating Icons

Содержание iX-1001

Страница 1: ...SURVEYING INSTRUMENTS Class 3R Laser Product OPERATOR S MANUAL 1008477 02 B iX 1000 series iX 500 series intelligence X ellence Station ...

Страница 2: ...or additional information Indicates supplementary explanation Indicates an explanation for a particular term or operation MEAS etc Indicates Operation icons on the display and window dialog buttons ESC etc Indicates keys on the operation panel Screen title etc Indicates screen titles Notes regarding manual style Except where stated iX means iX 1000 500 series in this manual Model with display on t...

Страница 3: ...unication 41 9 5 Cellular Settings and Communication 44 9 6 Connecting via USB Cable 47 9 7 Inserting USB Flash Drive 50 10 TARGET SIGHTING AND MEASUREMENT 51 10 1 Auto Pointing and Auto Tracking Settings 53 10 2 Auto Pointing and Auto Tracking Function for Target Sighting Measurement 56 10 3 Manually Sighting the Target 59 11 ANGLE MEASUREMENT 60 11 1 Measuring the Horizontal Angle between Two Po...

Страница 4: ...trument Conditions Power 118 19 7 Instrument Conditions Instrument 119 19 8 Instrument Conditions Unit 120 19 9 Instrument Conditions Password 121 19 10Customizing Screen Controls 122 19 11Instrument Conditions Date and Time 122 19 12Allocating Operating Icons 125 19 13Changing Starkey Mode Icons 128 19 14Restoring Default Settings 130 20 WARNING AND ERROR MESSAGES 131 21 CHECKS AND ADJUSTMENTS 13...

Страница 5: ...combustible materials An explosion could occur Do not perform disassembly or rebuilding Fire electric shock burns or hazardous radiation exposure could result Never look at the sun through the telescope Loss of eyesight could result Do not look at reflected sunlight from a prism or other reflecting object through the telescope Loss of eyesight could result Direct viewing of the sun during sun obse...

Страница 6: ...ers into fire An explosion could occur resulting in injury To prevent shorting of the battery in storage apply insulating tape or equivalent to the terminals Otherwise shorting could occur resulting in fire or burns Do not use the battery or the battery charger if its terminals are wet Resultant poor contact or shorting could lead to fire or burns Do not connect or disconnect power supply plugs wi...

Страница 7: ...h a cardiac pacemaker Otherwise the pacemaker may be adversely affected by the electromagnetic waves produced and cease to operate as normal Do not use onboard aircraft The aircraft instrumentation may malfunction as a result Do not use within the vicinity of automatic doors fire alarms and other devices with automatic controls as the electromagnetic waves produced may adversely affect operation r...

Страница 8: ...nt can be removed When operating the instrument with the handle attached always make sure that the handle is securely fixed to the instrument body with the handle locks Precautions concerning water and dust resistance The instrument conforms to IP65 specifications for waterproofing and dust resistance when battery cover connector cap and the external interface hatch are closed Be sure to correctly...

Страница 9: ...ditions are treated as being outside the scope of the product warranty Maintenance Wipe off moisture completely if the instrument gets wet during survey work Always clean the instrument before returning it to the case The lens requires special care First dust it off with the lens brush to remove tiny particles Then after providing a little condensation by breathing on the lens wipe it with the sil...

Страница 10: ...act your local dealer in advance Exceptions from responsibility The user of this product is expected to follow all operating instructions and make periodic checks hardware only of the product s performance The manufacturer or its representatives assumes no responsibility for results of faulty or intentional usage or misuse including any direct indirect consequential damage or loss of profits The m...

Страница 11: ...injury is caused by exposure to the laser beam seek immediate medical attention from a licensed ophthalmologist Do not look directly into the laser beam source or guide light source Doing so could cause permanent eye damage Do not stare at the laser beam Doing so could cause permanent eye damage Never look at the laser beam through a telescope binoculars or other optical instruments Doing so could...

Страница 12: ... could cause serious injury Only those who have been received training as per the following items shall use this product Read this manual for usage procedures for this product Hazardous protection procedures read this chapter Requisite protective gear read this chapter Accident reporting procedures stipulate procedures beforehand for transporting the injured and contacting physicians in case there...

Страница 13: ...orizontal Jog 18 Power key 19 Speaker 20 Trigger key 21 Keyboard 5 2 Display Functions 22 Serial External power source connector 23 Stylus pen 24 Levelling foot screw 25 Base plate 26 Tribrach clamp 27 Display unit 28 Optical plummet eyepiece 29 Optical plummet focussing ring 30 Telescope knob 31 Telescope eyepiece 32 Telescope eyepiece screw 33 Telescope focussing ring Instrument height mark The ...

Страница 14: ... Jogs Trigger key When the Trigger key is pressed the instrument carries out the operation indicated by the orange Operating icon on the screen This allows the user to continue operation without having to return to the display to press Operating icons Wireless antenna The wireless antenna allows communication via wireless technologies Handle the antenna with care The antenna may be damaged if stru...

Страница 15: ...tach detaching button and then move the handle to the right while sliding the attach detaching slider to the direction indicated in the arrow 2 Along with the step 1 lift it up to detach Detaching attaching the Standard Handle Auto Pointing model The carrying handle can be removed from the instrument when the prism is located at the zenith etc 1 To remove it loosen the handle rocking screws 2 To a...

Страница 16: ...the instrument to detach Attaching the instrument to the tribrach 1 Check that the tribrach locking screw has been loosened 2 Align 1 and 2 and lower the instrument onto the tribrach 3 Turn the tribrach clamp clockwise to tighten 4 Turn the tribrach locking screw 3 clockwise to tighten Always fully tighten the tribrach locking screw to reduce adverse effects of motor operation on accuracy and ensu...

Страница 17: ...hen a program is activated or quit 4 2 Mode Structure OK PRG ۻ ESC ۻ PRG Program screen OBSERVE MENU Version CONFIG SHV display Distance display Graphic display Version display mode Program mode Starkey mode Basic mode Observation mode Display switchable Menu mode Top menu Config mode Program activate icons Available only when a program is activated 1 1 The previous screen PRG is pressed is recove...

Страница 18: ...e frequency band as Bluetooth communications As a result using the iX within proximity to the above devices may result in interference causing communication failure or reduction of transmission speed Bluetooth devices when Wireless LAN function Although a radio station license is not required for this instrument bear in mind the following points when using Bluetooth technology for communication Re...

Страница 19: ...oreover wood glass and plastic containing metal frames plates foil and other heat shielding elements as well as coatings containing metallic powders may adversely affect Bluetooth communication and concrete reinforced concrete and metal will render it impossible Use a vinyl or plastic cover to protect the instrument from rain and moisture Metallic materials should not be used The direction of the ...

Страница 20: ...it Switching the Laser pointer Guide light ON OFF Switching function 19 7 Instrument Conditions Instrument Changes can also be made by tapping the icon on Status icon or in Starkey mode 5 2 Display Functions Status icons 5 4 Starkey Mode 5 1 Basic Key Operation Switches the reticle illumination and key light On Off When Key light is On backlight brigthtness goes down Switches to Starkey mode previ...

Страница 21: ...nput a decimal point during numeric input mode Input code in alphabetic input mode Input a plus or minus sign during numeric input mode Input code in alphabetic input mode ESC Cancel the input data α S P Shift to the next item B S Delete a character on the left S P Input a blank space increments by 1 when setting the date and time Move the cursor left right Move the cursor up down Enter Select acc...

Страница 22: ...uch panel can be temporarily de activated This is especially useful when cleaning the display To de activate tap on the Status icon The screen below is displayed Allocating 19 13 Changing Starkey Mode Icons The touch panel cannot be operated while the above message is displayed Press ESC to cancel the message and re activate the touch panel Keyboard operation is partially limited during the Tempor...

Страница 23: ...nce Display status can be switched between SD slope distance HD horizontal distance VD vertical distance 19 2 Observation Conditions Dist 2 Vertical angle The Vertical angle display can be switched between Zenith Z 0 Horiz H 0 Horiz H 90 To switch vertical angle slope in press ZA when allocated to the Observation mode screen 19 1 Observation Conditions Angle Tilt Program activate Mode switch icons...

Страница 24: ...ing Operating Icons Horizontal distance and height difference are also displayed in SHVdist display of Observation mode Measuring screen Observation mode screen Graphic display Following operations are available by switching Operating icons CNFG In Graphic configuration the user can specify the orientation of the graphic display and which point target or station to set at the center of the display...

Страница 25: ...nstrument Tapping icons will switch between the relevant options for that item Tapping and holding will display a list of all available options for that item and in certain cases a link to the configuration screen for that item Allocation of the icons of the Status icon corresponds with that of Starkey mode About icons 5 4 Starkey Mode Number Status icons ...

Страница 26: ...ut characters Tab Moves the cursor to the next text box CAP Alternates between upper and lower case alphabetic characters and numbers symbols Shift Alternates between upper and lower case alphabetic characters and numbers symbols Is canceled after inputting a single character Ctl No function Del Delete the character to the left right or deletes the entire text in the active section Move the cursor...

Страница 27: ...are described below The numbers correspond to above icons 1 Battery icon Remaining battery power indicator Temperature 20 C EDM on The remaining battery power displayed when distance measurement is in progress may differ to that displayed at other times You can jump to the Power config screen 19 6 Instrument Conditions Power When using standard battery BDC70 Level 3 Full power Level 2 Plenty of po...

Страница 28: ...ting when measuring the distance Measure the distance only Start Auto Tracking TRK Off is displayed when performing Auto Tracking or when in Prism wait status Tap to quit Auto Tracking Begin searching Rotates the instrument 180 One of the following icons will be displayed while the motor is in operation to indicate the current status of the instrument Rotating Rotating at fixed velocity Searching ...

Страница 29: ...vation Conditions Angle Tilt Horizontal and vertical tilt angles compensated blue No compensation Only vertical tilt angle compensated green is displayed when the instrument is out of level 6 Communication status with external devices icon Selection of communication method with external devices You can jump to the Communication config screen Setting of RS232C communication 9 3 Connection via RS232...

Страница 30: ...to the Atmos config screen 19 4 Observation Conditions Atmosphere 10 Internet communication status Connection status of internet communication is displayed You can jump to the Internet config screen 9 4 Wireless LAN Settings and Communication 9 5 Cellular Settings and Communication Configuration of internet communication Connection status to a router is displayed as follows i Wireless LAN connecti...

Страница 31: ...isplayed Less than 20 20 to 50 More than 50 Tap and hold disk icon in the Status icon to check the detail of the disk usage Usage space of disk capacity of the instrument Free space of disk capacity of the instrument Disk capacity of the instrument Usage space of disk capacity of the external disk connected to the instrument Free space of disk capacity of the external disk connected to the instrum...

Страница 32: ...age the battery should be charged at least once every six months Batteries generate power using a chemical reaction and as a result have a limited lifetime Even when in storage and not used for long periods battery capacity deteriorates with the passage of time This may result in the operating time of the battery shortening despite having been charged correctly In this event a new battery is requi...

Страница 33: ...ached battery BDC70 Before removing the battery turn off the power to the instrument If the battery is removed while the power is switched on a warm boot may occur File and folder data may be lost as a result Do not open the battery cover while the power is on Do not damage the projected sensor inside the battery cover Also be careful not to shut the battery cover on your fingers When installing r...

Страница 34: ...ument on the tripod head Supporting it with one hand tighten the centering screw on the bottom of the unit to make sure it is secured to the tripod 3 Looking through the optical plummet eyepiece turn the optical plummet eyepiece to focus on the reticle Turn the optical plummet focussing ring to focus on the survey point 4 Adjust the levelling foot screws to center the survey point in the optical p...

Страница 35: ... Press L OFF to turn the laser plummet off Alternatively the laser plummet will switch off automatically when going to another screen Visibility of the laser spot may be affected when operating in direct sunlight In this event provide shade for the survey point PROCEDURE 1 Perform the centering procedure 7 1 Centering 2 Roughly center the bubble in the circular level by either shortening the tripo...

Страница 36: ... for the Y direction When the bubble is in the center proceed to step 5 5 Loosen the centering screw slightly Looking through the optical plummet eyepiece slide the instrument over the tripod head until the survey point is exactly centered in the reticle Retighten the centering screw securely If the instrument is levelled using laser plummet emit the laser plummet beam and check it again 7 2 Level...

Страница 37: ... of level Level the instrument once again using circular level then display Tilt Press and hold on Status icon or in Starkey mode then select Go to Tilt screen 5 4 Starkey Mode 5 Tilt angle compensation icon Tilt crn in Angle Tilt should be set to No if the display is unsteady due to vibration or strong wind 19 1 Observation Conditions Angle Tilt Resume function The Resume function redisplays the ...

Страница 38: ...the screen and tap the cross hairs displayed on the screen with the stylus pen Tap the cross hairs on the other side of the display as well For the model with display on the both sides only Touch panel configuration can be performed at any time during normal operation by pressing PNL CAL in Display 19 5 Instrument Conditions Display If you are experiencing problems with the instrument and suspect ...

Страница 39: ...ment is reset and powers ON as normal 19 14 Restoring Default Settings Problems Powering OFF When the instrument cannot be powered OFF as normal depress the reset button with the tip of the stylus pen Pressing the Reset button may result in file and folder data being lost The instrument can be powered ON OFF from an external device such as a computer or data collector The password must be input af...

Страница 40: ...tooth Wireless Technology Wireless LAN The Bluetooth module incorporated in the instrument can be used for communication with Bluetooth devices such as data collectors Bluetooth connection mode Communication between a pair of Bluetooth devices requires one device to be set as the Master and the other as the Slave iX is always Slave and the paired data collector will be the Master when performing m...

Страница 41: ...y setting 1 Check sum Yes No 2 Controller Remote 2 Way 2 Way Remote Changing communication settings during Bluetooth communication will cancel the connection No changes for the factory setting are necessary as long as connecting to a recommended program on the data collector If connection can not be established check the communication settings of iX and the data collector 7 Select Bluetooth in Com...

Страница 42: ...t to 0123 at the factory 10 Press Enter to finish settings Move on to the Bluetooth communication 9 2 Communication between the iX and Companion Device When selecting T type in step 3 the following items are displayed 1 REC Type REC A newly measured data is output REC B displayed data is output 2 Terminate ETX ETX CR ETX CR LF 3 TRK State On with track state information Off 4 Ack mode On Off Termi...

Страница 43: ...tion causes instrument battery power to be depleted at a rate higher than that for normal operation Check that the companion device data collector computer or cellular phone etc is turned on and the relevant Bluetooth settings are complete All communication settings will be changed to factory settings when a cold boot is performed Comms setup will need to be performed again 9 1 Wireless Communicat...

Страница 44: ...ings 1 Power OFF the instrument and connect the instrument and a data collector with a interface cable Cables 25 ACCESSORIES Insert the interface cable to the serial external power source connector tightly and then turn it 2 Select Comms in Config mode 3 Select Comms mode in Communication Setup 4 Set Comms mode to RS232C 9 3 Connection via RS232C Cable ...

Страница 45: ...2400 4800 9600 19200 38400bps 2 Data bits 7 8 bits 3 Parity Not set Odd Even 4 Stop bit 1 2 bits 7 Press Enter to finish settings A program installed on the instrument can communicate with an external device by connecting to Internet via Wireless LAN PROCEDURE 1 Select Comms in Config mode 2 Select Internet in Communication Setup 9 4 Wireless LAN Settings and Communication ...

Страница 46: ...table to a router Input the IP address so that it is not the same of the router to be connected Avoid the overlapped range of IP address assigned via DHCP server Example Set 192 168 0 3 when the router address is 192 168 0 1 2 Subnet Mask The same value of the router to be connected 3 Gateway IP address of the router to be connected 5 Press DNS Setting in Internet Set DNS Setting to Auto when usin...

Страница 47: ...dary IP address of DNS secondary server 3 WINS Primary IP address of WINS primary server 4 WINS Secondary IP address of WINS secondary server 6 Press Connect in Internet to move to the communication setting screen 7 Select an access point from the searched Wireless LAN access points and press Connect It may take a few seconds until wireless LAN access points list is displayed 8 Set necessary secur...

Страница 48: ...servers for each server are available to resolve IP address in case of a server system down A program installed on the instrument can communicate with an external device by connecting to Internet via Cellular connection SIM card may not be used depending on the model the country or the area where the instrument is purchased Some SIM cards may not be used depending on the carriers or the contact de...

Страница 49: ...ing the Battery 2 Insert a SIM card to the SIM card slot Do not use SIM card converter adaptor Inserted adaptor may not be taken out or it may damage the inside of the SIM card slot 3 Close the battery cover 4 Select Comms in Config mode 5 Select Internet in Communication Setup SIM card slot ...

Страница 50: ...HAP When IMEI is necessary for the activation of your SIM card check the IMEI displayed in this screen 7 Press Search to search connection ready carriers in the immediate vicinity of the instrument Select the carrier set in step 6 and press OK Press Status to display the communication status Displayed items are as follows Carrier Name Selected carrier s name Level Connection status is displayed in...

Страница 51: ...g USB port 2 the instrument and a computer can be communicated There are USB mode and Mobile mode USB port The instrument has two different USB ports Each port is used for connection to different types of devices TOPCON CORPORATION cannot guarantee that all USB devices are compatible with the iX USB ports Use a computer WindowsVista 7 is based and USB connection is capable Remove the USB cable fro...

Страница 52: ...e connection 3 Press the power key on the side of the instrument while pressing Enter to display a message box asking whether to boot USB mode then press YES The screen of the instrument will be USB Mode instrument may not be displayed as Removable Disk It depends on Windows settings Follow the instructions below to ensure that the instrument continues to operate normally during USB transfer Do no...

Страница 53: ...boot USB mode then press NO The synchronous software is effective instrument may not be displayed as Removable Disk It depends on Windows settings Follow the instructions below to ensure that the instrument continues to operate normally during USB transfer Do not change the folder hierarchy or folder names in Removable Disk Do not format the removable disk on the computer 4 If synchronous software...

Страница 54: ...lide up the catch on the external interface hatch to open 9 6 Connecting via USB Cable 2 Insert the USB flash drive into the USB port 1 When using a USB flash drive with 4 metal terminals on the surface insert it with the terminal facing forwards to avoid damaging the USB port 3 Close the external interface hatch until a click is heard 4 Save data in the USB flash drive or import data from the mem...

Страница 55: ...ng a prism located at the zenith manually use optional accessory diagonal eyepiece DE30 10 3 Manually Sighting the Target If more than one prism is located in the field of sight during Auto Pointing the prism closer to the reticle is sighted An operation error may occur and the instrument may not be able to find the prism depending on the prism installation status or measuring conditions A prism b...

Страница 56: ...the measurement error is caused is illustrated below Targets available for the iX 24 TARGET SYSTEM 360 prism 360 prisms reduce the possibility of lost prism during Auto Tracking measurement regardless of the direction of the prism Details of 360 prisms 24 TARGET SYSTEM Performing high accuracy measurement using 360 prism 27 1 High Accuracy with the 360 Prism Prism Prism constant correction value N...

Страница 57: ...tting to Search when performing Auto Pointing only Set 2 Track Setting to Track when performing Auto Tracking Set 7 Tracking Meas to 9 Wait time only when performing Auto Tracking Items set and options Factory setting 1 AUTO AIM Fine Rapid 2 Track Setting None Search Auto Pointing model None Search Track Auto Tracking model 3 Srch method G S R C 4 Search pattern 1 2 3 5 Vertical 0 to 90 15 in 1 st...

Страница 58: ...at the prism is sighted at the approximate center of the field of view Auto Pointing is complete Although this setting provides greater accuracy when supporting the pole by hand hand movements will result in Auto Pointing taking too long to complete and a Time out error will occur When Rapid is set however Auto Pointing can be performed even with slight instability of prism position or minor shift...

Страница 59: ...tive when measuring a moving object In the Fixed Averaging setting the angle value corrected by the image sensor is averaged and then fixed when the iX automatically detects the rest state of target during Auto Tracking The angle value will be fixed until the target starts moving again Therefore the angle display during the target is in resting state will be stabilized and scintillation effect wil...

Страница 60: ...lf of the instrument rotate and target auto search begins When the target is found the instrument sights the prism and stops Allocating the SRCH Operating icon 19 12 Allocating Operating Icons PROCEDURE Measurement using Auto Pointing and Auto Tracking function Auto Tracking model only 1 Use the sighting collimator to aim the objective lens in the general direction of the target The vertical and h...

Страница 61: ...tus and when the prism comes into the field of view the instrument starts Auto Tracking Forecast time duration of search in predicted direction and Wait time settings 10 1 Auto Pointing and Auto Tracking Settings step 4 Difference in search and measuring distance operation Operating icons related to sighting and measuring distance are different between Auto Pointing models and Auto Tracking models...

Страница 62: ...ms Auto Pointing then angle distance measurement Performs Turning operation then distance measurement Auto Tracking Performs Auto Pointing then distance measurement Auto Tracking Performs angle and distance measurement RC Rotates directly in the direction of the Remote Controller then performs Auto Pointing Auto Tracking Rotates in the direction specified by the Remote Controller then performs Aut...

Страница 63: ...he target Turn the telescope focussing ring to focus on the target Turn the vertical and horizontal fine motion screws to align the target with the reticle The last adjustment of each fine motion screw should be in the clockwise direction 4 Readjust the focus until there is no parallax Readjust the focus with the focussing ring until there is no parallax between the target image and the reticle El...

Страница 64: ... Icons Use the 0SET function to measure the included angle between two points The horizontal angle can be set to 0 at any direction PROCEDURE 1 Sight the first target as at right 10 TARGET SIGHTING AND MEASUREMENT 2 Press 0SET 0SET will flash so press 0SET again The horizontal angle at the first target becomes 0 3 Sight the second target The displayed horizontal angle HA R is the included angle be...

Страница 65: ...o be performed with coordinate and azimuth input 13 2 Azimuth Angle Setting 4 Press OK to confirm the input value and display the new horizontal angle 5 Sight the second target The horizontal angle from the second target to the value set as the horizontal angle is displayed Pressing HOLD performs the same function as above Press HOLD to set the displayed horizontal angle Then set the angle that is...

Страница 66: ...ilt PROCEDURE 1 Sight the point you will use as the reference angle and set it as the reference angle Sight the reference point and press 0SET or input the reference point angle 11 1 Measuring the Horizontal Angle between Two Points Horizontal Angle 0 11 2 Setting the Horizontal Angle to a Required Value Horizontal Angle Hold 2 Press MOTOR Enter the vertical and horizontal angles in the Motor disp...

Страница 67: ...ont Nullifies the current measurement position then continues Turning operation The following explains angle measurement and the features used to output measurement results to a computer or other external devices Setting procedures 9 CONNECTING TO EXTERNAL DEVICES Cables 25 ACCESSORIES Output format and command operations Communication manual PROCEDURE 1 Connect instrument and external device Sett...

Страница 68: ... the target settings accurate measurement results cannot be obtained Accurate measurement results cannot be obtained if the objective lens is dirty Dust it off with the lens brush first to remove minute particles Then after providing a little condensation by breathing on the lens wipe it off with the silicon cloth During reflectorless measurement if an object obstructs the light beam used for meas...

Страница 69: ...t is returned When is not displayed accurately resight the target BEEP OFF Sets a buzzer sound when measurement is possible Press to switch on and off MEAS Returns to Observation mode and starts angle and distance measurement regardless of Track Setting setting 3 Press OFF to finish signal checking Press ESC to return to the previous screen When is displayed persistently but is not contact your lo...

Страница 70: ...o Pointing and Auto Tracking Settings Caution The laser beam is emitted during Auto Pointing and Auto Tracking PROCEDURE 1 Face the instrument in the direction of the target Use the sighting collimator to aim the instrument and telescope toward the target 10 TARGET SIGHTING AND MEASUREMENT 12 2 Using the Guide Light in Distance Measurement Light status Meaning Slow flashing Red and green simultane...

Страница 71: ...ment automatically stops after a single measurement During fine average measurement the distance data is displayed as SD1 SD2 to SD9 When the designated number of measurements has been completed the average value of the distance is displayed in the SDA line The distance and angle that are most recently measured remain stored in the memory until the power is off and can be displayed at any time by ...

Страница 72: ...25 ACCESSORIES Output format and command operations Communication manual PROCEDURE 1 Connect instrument and external device Setting procedures 9 CONNECTING TO EXTERNAL DEVICES 2 Sight the target point 3 Press HVDOUT T or HVDOUT S to measure the distance and output the data to the external device 4 Press STOP to stop outputting data and return to Observation Mode 12 4 Distance Measurement and Outpu...

Страница 73: ...s z1 It is possible to allocate Operating icons in measurement menus to suit various applications and the ways that different operators handle the instrument 19 12 Allocating Operating Icons PROCEDURE 1 Set the target directly under or directly over the object and measure the target height with a tape measure etc Press HT and enter the target height 2 Select REM in Menu 3 Sight the target and pres...

Страница 74: ...ement is started The height from the ground to the object is displayed in Ht Press STOP to stop the measurement To re observe the target sight the target then press MEAS To continue REM measurement press REM When measurement data already exists select REM in Menu as in step 2 to proceed to step 4 and start REM measurement Press STOP to stop the measurement ...

Страница 75: ...sible to allocate Operating icons in measurement menus to suit various applications and the ways that different operators handle the instrument 19 12 Allocating Operating Icons Before performing coordinate measurement enter instrument station coordinates and instrument height Occupy on the software represents instrument station PROCEDURE 1 First measure the instrument height with a tape measure et...

Страница 76: ...ght station is calculated PROCEDURE Entering coordinates 1 Select Backsight setup in Coordinate Backsight setup can also be displayed from the screen in step 4 of 13 1 Entering Instrument Station Data 2 Tap the screen title to display popup and select Key in coord display Enter the backsight station coordinates SRCH Performs Auto Pointing Rotates the instrument in the direction of the backsight Az...

Страница 77: ...up in Coordinate Backsight setup is displayed Backsight setup can also be displayed from the screen in step 4 of 13 1 Entering Instrument Station Data 2 Tap the screen title to display popup and select Key in angle display Enter the desired angle in H ang SRCH Performs Auto Pointing Rotates the instrument in the direction of the backsight 3 Press OK to set the input values Coord measurement is dis...

Страница 78: ...None input azimuth angle only 0 SET horizontal angle set to 0 The coordinate values of the target can be found by measuring the target based on the settings of the instrument station and backsight station The coordinate values of the target are calculated using the following formulae N1 Coordinate N0 S x sinZ x cosAz E1 Coordinate E0 S x sinZ x sinAz Z1 Coordinate Z0 S x cosZ ih th N0 Station poin...

Страница 79: ...play popup and select Graphic display The coordinates are displayed on a graph Press HT to set the instrument station data again When the target height of the next point is different input it before the observation 3 Sight the next target and press MEAS to begin measurement Continue until all targets have been measured 4 When coordinate measurement is completed press ESC to return to Coord measure...

Страница 80: ...surement and between 3 and 10 known points by angle measurement The more known points there are and the more points there are whose distance can be measured the higher the precision of the coordinate value calculation It is possible to allocate Operating icons in measurement menus to suit various applications and the ways that different operators handle the instrument 19 12 Allocating Operating Ic...

Страница 81: ...ting the coordinates and target height for the first known point press NEXT to move to the second point Press PREV to return to settings for the previous point When all required known points have been set press OK 4 Sight the first known point and press MEAS to begin measurement The measurement results are displayed on the screen Press ANGLE to measure the angle only 14 1 Coordinate Resection Meas...

Страница 82: ...m quantity of observation data required for the calculation is present CALC is displayed AUTO will be displayed for the 3rd point onwards Pressing AUTO will rotate the instrument to the next point and start auto measurement Press STOP during auto measurement to display a confirmation message Press YES in this message to return to the first point measured using auto measurement Measurement can now ...

Страница 83: ...g easting and elevation coordinates of each point are displayed by pressing DETAIL 8 If there are problems with the results of a point align the cursor with that point and press OMIT OMIT is displayed to the right of the point Repeat for all results that include problems 9 Press RE_CALC to perform calculation again without the point designated in step 8 The result is displayed If there are no prob...

Страница 84: ...nd press YES to set the azimuth angle of the first known point as the backsight point and return to Resection Menu Press NO to return to Resection Menu without setting the azimuth angle Horizontal angle settings H set horizontal angle to measured value H Az set horizontal angle to the same value as azimuth angle Az set azimuth angle only It is also possible to perform resection measurement by pres...

Страница 85: ...Select Elevation to display Resection Known point 3 Input the known point After setting the elevation and target height for the first known point press NEXT to move to the second point Press PREV to return to settings for the previous point When all required known points have been set press OK 4 Sight the first known point and press MEAS to begin measurement The measurement results are displayed o...

Страница 86: ...y are displayed in Result Standard deviation values for each point are displayed in Detail 7 If there are problems with the results of a point align the cursor with that point and press OMIT OMIT is displayed to the right of the point Repeat for all results that include problems 8 Press RE CALC to perform calculation again without the point designated in step 7 The result is displayed If there are...

Страница 87: ...to finish resection measurement and return to Resection Menu Only Z elevation of the instrument station coordinate is set N and E values are not overwritten Resection calculation process The NE coordinates are found using angle and distance observation equations and the instrument station coordinates are found using the method of least squares The Z coordinate is found by treating the average valu...

Страница 88: ...one of the following measures 1 Move the instrument station as close as possible to the center of the triangle 2 Observe one more known point which is not on the circle 3 Perform a distance measurement on at least one of the three points In some cases it is impossible to calculate the coordinates of the instrument station if the included angle between the known points is too small It is difficult ...

Страница 89: ...e Slope distance difference Displayed value slope distance measured slope distance slope distance setting out data Horizontal distance or height difference can be input in the above formula Coordinate difference Displayed value coordinates measured N setting out coordinates N coordinates of setting out data E or Z coordinates can be input in the above formula Height difference REM setting out meas...

Страница 90: ...tation 15 1 Using the Guide Light in Setting out Measurement Light status Meaning Slow flashing Red and green simultaneously Waiting Search error error screen only Fast flashing Red and green simultaneously Searching in progress Measuring continuous measurement Returned signal checking in progress Auto Tracking in progress Auto Tracking model only Auto Tracking in predicted direction Auto Tracking...

Страница 91: ...Instrument Station Data 3 Set the azimuth angle for the backsight station Press OK to return to Setting out 13 2 Azimuth Angle Setting 4 Select SO data setting in Setting out In the distance mode that conforms to your measurement requirements enter the included angle between the reference point and the setting out point in SO H ang and the distance slope distance horizontal distance or height diff...

Страница 92: ...in this range both arrows will be displayed to indicate that the target position is correct 6 Position the target on the line of sight and press MEAS to begin distance measurement The distance and direction to move the target until the setting out point is located is displayed on the instrument The sighting point measurement results currently installed position of the target are displayed Movement...

Страница 93: ...nce and slope distance REM Tap the screen title to display popup and select Graphic display to show the current position on a graph 7 Move the target until the distance to the setting out point reads 0 m When the target is moved within the allowed range all distance and position arrows are displayed 8 Press ESC to return to Setting out Set the next setting out point to continue setting out measure...

Страница 94: ...rdinate location can be set out Previously recorded setting out points can be placed in order Up to 50 points can be recorded To find the Z coordinate attach the target to a pole etc with the same target height PROCEDURE 1 Select Setting out in Menu to display Setting out 2 Set the instrument station and if necessary enter data for Backsight setup 15 2 Distance Setting out Measurement steps 2 to 3...

Страница 95: ...en of step 3 and press OK to display Set out Coords 5 Position the target on the line of sight and press H TURN to automatically rotate the instrument until the angle of the setting out point reads 0 Press MEAS to begin distance measurement The distance and direction to move the target until the setting out point is located is displayed on the instrument The sighting point measurement results curr...

Страница 96: ...ion to the setting out point from this position The Graph 2 the position of the setting out point square and the current location of the mirror circle Move the target to find the correct distance 0 is displayed to the setting out point Movement indicators 15 2 Distance Setting out Measurement step 6 Height difference direction Position of poleman Setting out point Position of poleman ...

Страница 97: ...o measure the target height height from the survey point to the target 2 Select Setting out in Menu to display Setting out 3 Set the instrument station and if necessary enter data for Backsight setup 15 2 Distance Setting out Measurement steps 2 to 3 4 Select SO data setting In Setting out to display SO data setting Press Shvr until the distance input mode is SO Height Input height from the survey...

Страница 98: ...ence and direction to move the target until the sighting point and setting out point are located is displayed on the instrument Press STOP to stop measuring Find the setting out point by moving the telescope until SO Height Diff reads 0 m Movement indicator Red indicates that target position is correct Move the telescope near the zenith Move the telescope near the nadir Telescope direction is corr...

Страница 99: ...95 15 SETTING OUT MEASUREMENT Tap the screen title to display popup and Graphic display can be selected 8 Press ESC to return to SO data setting ...

Страница 100: ... Instrument Station Data Backsight setup 13 2 Azimuth Angle Setting It is possible to allocate Operating icons in measurement menus to suit various applications and the ways that different operators handle the instrument 19 12 Allocating Operating Icons Finding it by entering the horizontal distance from the target point to the offset point When the offset point is positioned to the left or right ...

Страница 101: ...Input the following items 1 Direction of the offset point 2 Horizontal distance from the target point to the offset point Direction of offset point 6 Sight the offset point and press MEAS in the screen of step 5 to start measurement Press STOP to stop the measurement The measurement results are displayed Press HVD nez to switch results for the target point between distance angle values and coordin...

Страница 102: ...e of the target point PROCEDURE 1 Set the offset points close to the target point making sure the distance from the instrument station to the target point and the height of the offset points and the target point are the same then use the offset points as the target 2 Select Offset in Menu to display Offset 3 Select OffsetANG 4 Sight the offset point and press MEAS to start measurement Press STOP t...

Страница 103: ... the target point It is possible to make this measurement easily using the optional equipment the 2 point target 2RT500 K How to use 2 point target 2RT500 K Install the 2 point target with its tip at the target point Face the targets toward the instrument Measure the distance from the target point to the 2nd target Make sure reflector type is set correctly 19 3 Observation Conditions Reflector Tar...

Страница 104: ...nd use the offset points as the target 2 Select Offset in Menu to display Offset 3 Select Offset2D 4 Press CNFG and input the distance from the 2nd target to the target point in Offset dist Set reflector settings and press OK to confirm 5 Sight the 1st target and press MEAS to start measurement Press STOP to stop the measurement ...

Страница 105: ...Press STOP to stop the measurement The measurement results are displayed 7 Press YES in the measurement result screen of the 2nd target to display results for the target point Press HVD nez to switch results for the target point between distance angle values and coordinate elevation values 8 Press OK in the screen in step 7 to return to Offset ...

Страница 106: ...t results can be displayed as the gradient between two points It is possible to allocate Operating icons in measurement menus to suit various applications and the ways that different operators handle the instrument 19 12 Allocating Operating Icons PROCEDURE 1 Select MLM in Menu When measurement data already exists the screen of step 3 is displayed and measurement starts 2 Sight the starting positi...

Страница 107: ...grade horizontal distance and height difference between multiple points and the starting position can be measured this way Press MEAS to re observe the starting position Sight the starting position and press MEAS When MOVE is pressed the last target measured becomes the new starting position to perform missing line measurement of the next target 17 2 Changing the Starting Point 5 Press ESC to end ...

Страница 108: ... in 17 1 Measuring the Distance between 2 or more Points 2 After measuring the targets press MOVE Press YES in the confirmation message window Press NO to cancel measurement 3 The last target measured is changed to the new starting position 4 Perform missing line measurement following steps 4 to 5 in 17 1 Measuring the Distance between 2 or more Points 17 2 Changing the Starting Point ...

Страница 109: ...ed when specifying an enclosed area Be sure to observe points on an enclosed area in a clockwise or counterclockwise direction For example the area specified by entering point numbers 1 2 3 4 5 or 5 4 3 2 1 implies the same shape However if points are not entered in numerical order the surface area will not be calculated correctly Slope area The first three points specified are used to create the ...

Страница 110: ... are displayed Press STOP to stop measuring 3 The measurement results are displayed Press YES to confirm The value of point 1 is set in Pt_01 4 Repeat steps 2 to 3 until all points have been measured Points on an enclosed area are observed in a clockwise or counterclockwise direction For example the area specified by entering point numbers 1 2 3 4 5 or 5 4 3 2 1 implies the same shape ...

Страница 111: ...107 18 SURFACE AREA CALCULATION 5 Press CALC to display the calculated area 6 Press OK to return to Area calculation Press ESC twice to quit area calculation ...

Страница 112: ...dition Search Track settings 10 1 Auto Pointing and Auto Tracking Settings Communication settings 9 CONNECTING TO EXTERNAL DEVICES Instrument configurations 21 2 Tilt Sensor 21 4 Collimation 21 5 Image Sensor Reticle Select Obs condition in Configuration and select Angle Tilt Items set and options Factory setting Tilt crn tilt correction Yes H V No Yes V Tilt error No action Go to Tilt electric ci...

Страница 113: ...d changing the vertical angle by rotating the telescope will cause the displayed horizontal angle value to change Compensated horizontal angle Measured horizontal angle Tilt in angle tan Vertical angle When the telescope is directed close to the zenith or nadir angle tilt compensation is not applied to the horizontal angle Collimation correction The instrument has a collimation correction function...

Страница 114: ... measure road surface etc by sighting obliquely and to obtain rough measurement values Road can be selected only when Reflector type is set to N Prism Even if Road is selected Distance mode changes to Tracking automatically when Reflector type is set to other than N Prism Hdist The instrument calculates horizontal distance using slope distance values Horizontal distance display can be selected fro...

Страница 115: ...easurement set this item according to the measurement conditions When EDM ALC is set to Free the instrument s ALC will be automatically adjusted if an error occurs as a result of the amount of light received Set to Free when the target is moved during measurement or different targets are used When Hold is set the amount of light received will not be adjusted until continuous measurement is complet...

Страница 116: ...arget used with an external device or in a program installed in the Program mode prism constant correction value Reflective prisms each have their prism constant Set the prism constant correction value of the reflective prism you are using When selecting N Prism in Reflector prism constant correction value is set to 0 automatically 19 3 Observation Conditions Reflector Target ...

Страница 117: ... Dist reso Prism constant value can be input to the first decimal place 19 1 Observation Conditions Angle Tilt DEL Deletes the selected target 2 Press OK to confirm the settings PROCEDURE Adding a target 1 Press ADD in Reflector to display the list of candidate targets 2 Select a frequently used target from the list referring prism const correction value and aperture Up to a maximum of 6 targets c...

Страница 118: ...ist reso is 1 mm 0ppm Atmospheric correction factor returns to 0 and temperature and air pressure are set to the factory settings Atmospheric correction factor is calculated and set using the entered values of the temperature and air pressure Atmospheric correction factor can also be entered directly The Humidity is displayed only when the Humidity input is set to Yes When 0 1 mm is selected in Di...

Страница 119: ...itions With constant pressure a temperature change of 1 C an index change of 1 ppm With constant temperature a pressure change of 3 6 hPa an index change of 1 ppm To perform high accuracy measurements it is necessary to find the atmospheric correction factor from even more accurate temperature and pressure measurements and perform an atmospheric correction It is recommended that extremely precise ...

Страница 120: ...n pressing Backlight Normal 0 to 8 Auto Auto Backlight Off No 30 sec 1 min 5 min 10 min Key backlight Off On Color 1 2 monochrome Auto Auto Power saving mode Off On Press PNL CAL to display the touch panel calibration screen 8 1 Configuring the Touch Panel Power saving mode is displayed on the model with display on the both sides only 19 5 Instrument Conditions Display ...

Страница 121: ...the instrument is not operated for the selected time However the backlight will not be turned off when Backlight Reticle is selected Key backlight The key backlight can be set to ON or OFF When key backlight is set to ON the key backlight is lit OFF in conjunction with pressing Color setting Set Color to 2 monochrome when strong sunlight reduces visibility of the display When Auto is selected the ...

Страница 122: ...wer off To save power power to the instrument is automatically cut off if it is not operated for the set time Power off Remote When turned on using a Power on command power to the instrument is automatically cut off if it is not operated for the set time Command operations from a host computer can also be performed For details refer to Communication manual and ask your local dealer 19 6 Instrument...

Страница 123: ...o 1 min 5 min 10 min 30 min V manual No Yes Reticle lev 0 to 5 level 3 Volume Off 1 2 3 4 5 3 Reticle lev 19 5 Instrument Conditions Display Adjusting backlight brightness turning the reticle illumination and key backlight ON OFF Setting V manual to Yes 27 2 Manually Indexing the Vertical Circle by Face 1 2 Measurement Laser pointer off To save power the laser pointer is automatically turned off a...

Страница 124: ...eet is displayed only when Distance is set to Feet or Inch Inch Fraction of an inch Fraction of an inch is the unit used in the United States and expressed like the following example Even if inch is selected in this setting all the data including the result of area calculation are output in feet and all the distance values must be input in feet In addition when the inch display exceeds the range i...

Страница 125: ...ct Password Items set Old password Input current password New password Input the new password New password again Input the new password again Password can be from 3 up to 16 characters in length Input characters will be displayed as asterisks To deactivate the password function perform the new password setting procedure but enter a space in the New password box The password function will not be ca...

Страница 126: ... until they are revised again even when the power is cut off Press CLEAR in Customize Select screen 19 11 Customizing Screen Controls PROCEDURE Customizing screen controls step 2 to return all customized configurations including status icon settings and Operating icon allocations to their previous settings Screen controls cannot be set for the Graphic display When screen control settings are recor...

Страница 127: ...g screen controls 1 Select Customize to display Customize Select screen 2 Select the measurement mode in which you want to customize screen controls 3 Select Control 4 Press ADD to add a control drop down list Press DEL to delete the selected control ...

Страница 128: ...set the size thickness color and spacing of the font 7 Repeat steps 4 to 6 to customize more screen controls 8 Press ESC to finish customizing screen controls The modifications are stored in memory and previous screen is displayed The modifications are reflected in the relevant screens ...

Страница 129: ...lays of Set out Coords OK TRK On H TURN MEAS CNFG Functions that can be allocated to the Operating icons No functions set MEAS Distance and angle measurement 0SET Set horizontal angle to 0 H SET Set required horizontal angle SHV Switch the SHV display and SHVdist display can only be allocated to 1 above L R Select horizontal angle left right The capitalized letter in the Operating icon indicates t...

Страница 130: ... resection area calculation COORD Coordinates measurement S O Setting out measurement OFFSET Offset measurement A OFS Angle offset menu D OFS Distance offset menu 2D OFS Offset 2D menu MLM Missing line measurement REM REM measurement RESEC Resection measurement AREA Surface area measurement CNFG Set setting out accuracy can only be allocated to 2 and 3 above H TURN Rotate the instrument to the ent...

Страница 131: ...elect Operating icon 4 Select an Operating icon whose allocation you want to change Tap the Operating icon to display the Operating icon list 5 Select the desired Operating icon from the Operating icon list to allocate to the position specified in step 4 6 Repeat steps 4 to 5 to perform further key allocations ...

Страница 132: ...ng Starkey icon allocations step 2 to return all customized configurations including screen controls and Operating icon allocations to their previous settings When icon allocations are recorded and registered the previously recorded settings are cleared When the upper 8 icons allocations are recorded and registered the setting reflects to Status icon Icons that can be allocated to the Status icon ...

Страница 133: ...list 4 Select the new icon from the Starkey mode icon list The icon is allocated in the selected icon position 5 Repeat steps 3 to 4 to perform further icon allocations 6 Press ESC to finish allocating icons The allocated icons are stored in memory and the previous screen is restored The newly allocated icons appear in the relevant measurement screen ...

Страница 134: ...will not be canceled Resume function will be canceled PROCEDURE 1 To perform a cold boot while holding and S P press the power key on the side of the instrument All Settings will be cleared Are you sure is displayed 2 Press YES to continue Select NO and press Enter or press ESC to cancel 3 When the power is ON after the a cold boot the screen for configuring the touch panel is displayed Configure ...

Страница 135: ...ND MEASUREMENT Calculation error Coordinates identical to the known point coordinates observed during resection exist Set another known point so that the known point coordinates do not coincide During surface area calculation conditions necessary for calculations are not met Check conditions and try again An error occurred during calculation Checking Device Please wait several minutes to start the...

Страница 136: ...m the target Reflectorless not supported Auto Tracking cannot be performed in reflectorless mode Use the prism to carry out automatic sighting Remote Control communication err Communication between the Remote controller for Remote Control System and the instrument failed Check the status communications setup power supply cable connections etc of the Remote controller wireless modem and cables Shee...

Страница 137: ...t over range The tilt angle exceeds the tilt angle compensation range of the sensor Level the instrument again Time out Measurement is not carried out in the allotted time Reset and sight the prism and perform measurement again When designating the angle of rotation or automatically sighting the prism there is a problem with the positioning of the prism or the operation of the instrument and measu...

Страница 138: ...adjusting screws as this may damage the circular level PROCEDURE Checking and adjusting 1 Level while checking Tilt 7 2 Levelling Step 3 to 4 Tap Tilt angle compensation icon in the Status icon or in Starkey mode to display electric circular level If the tilt sensor is misaligned the circular level is not adjusted correctly 21 2 Tilt Sensor 2 Check the position of the bubble of the circular level ...

Страница 139: ...ROCEDURE Checking and adjusting 1 Carefully level the instrument If necessary repeat the procedures to check and adjust the bubble levels 2 Select Inst cons in Configuration 3 Select Tilt offset 4 Level the instrument again until the X Y tilt angles are 1 Wait a few seconds for the display to sdisplayilize 5 Press OK The top of the instrument and telescope rotate 180 from the current position Wait...

Страница 140: ... press NO to return to Instrument constants With this option you can check the perpendicularity of the reticle and the horizontal vertical positions of reticle lines Check the telescope reticle by sighting the target PROCEDURE Check 1 Perpendicularity of the reticle to the horizontal axis 1 Carefully level the instrument 2 Align a clearly visible target the edge of a roof for example on point A of...

Страница 141: ...the vertical angle B1 Example Horizontal angle A1 18 34 00 Vertical angle B1 90 30 20 4 While the telescope is in Face 2 sight the center of the target correctly and read out the horizontal angle A2 and the vertical angle B2 Example Horizontal angle A2 198 34 20 Vertical angle B2 269 30 00 5 Do the calculations A2 A1 and B2 B1 If A2 A1 is within 180 20 and B2 B1 is within 360 20 adjustment is unne...

Страница 142: ...nd 2 Perform the following procedures to correct the collimation offset constant Perform adjustment in weak sunlight and no scintillation It is recommended to perform collimation adjusting before the measurement especially when accurate result is desired in single face observations PROCEDURE Adjusting 1 Carefully level the instrument 2 Install a target at a point about 100 m in the horizontal dire...

Страница 143: ...the position of the image sensor in relation to the telescope reticle but if for whatever reason the telescope reticle and image sensor become misaligned automatic sighting of the center of the prism cannot be performed correctly and this will adversely affect angle measurement Check and adjust it as outlined below Perform check and adjustment in weak sunlight and no scintillation It may take up t...

Страница 144: ...irection approximately 50 meters from the instrument 3 Select Inst cons in Settings 4 Select Image Sensor Reticle offset 5 Use manual sighting to accurately sight the target 10 3 Manually Sighting the Target Sight not the center of the target plate but the center of the prism 6 Press OK Press STOP to stop the measurement Prism center ...

Страница 145: ...to perform the adjustment 8 Press OK to renew the offset value PROCEDURE Rechecking Sight the prism using the Auto Pointing function during a recheck Tilt crn should be se to Yes H V and Coll crn to Yes in Obs condition while performing checks 19 1 Observation Conditions Angle Tilt 1 Carefully level the instrument 2 Install a prism at a point about 50 m in the horizontal direction from the instrum...

Страница 146: ... careful that the tightening tension is identical for all the adjusting screws Also do not over tighten the adjusting screws as this may damage the circular level PROCEDURE Checking 1 Carefully level the instrument and center a survey point precisely in the reticle of the optical plummet 2 Turn the upper part through 180 and check the position of the survey point in the reticle If the surveying po...

Страница 147: ...th the grooves on the optical plummet The additive distance constant K of the instrument is adjusted to 0 before delivery Although it almost never deviates use a baseline with a known distance precision to check that the additive distance constant K is close to 0 several times a year and whenever the values measured by the instrument begin to deviate by a consistent amount Perform these checks as ...

Страница 148: ...e our service representative perform an adjustment Checks and adjustments are performed using an adjustment target Make an enlarged or reduced copy of the figure below PROCEDURE Checking 1 Level the instrument and emit the laser plummet beam 7 2 Levelling 2 Rotate the upper part horizontally and place a target so that it is aligned with the center of the circle created by the rotating laser plumme...

Страница 149: ... over tightened Turn screws clockwise to tighten 6 When the laser beam is on the upper lower part of Fig A the up down adjustment is made as follows Insert the provided hexagon key wrench into both the upper and lower screws Slightly loosen the upper lower screw and tighten the lower upper screw Make sure that the tightening tension for both screws is identical Continue to adjust until the laser b...

Страница 150: ...the target center 9 Re attach the laser plummet adjustment cap Tightening each of the fine adjustment screws moves the laser plummet beam in the directions shown below Up Right Left Down Tighten Up screw Tighten Left screw Tighten Down screw Tighten Right screw Fine adjustment screws Laser plummet adjustment cap pointing towards user ...

Страница 151: ... and purchasing process Cloud OAF update methods can be chosen from online or offline When updating the firmware mount a fully charged battery to the total station or use the external battery optional accessory This section explains the procedures of online Cloud OAF update PROCEDURE 1 Select Cloud OAF in Top to start Cloud OAF program 2 Press Option update Press ESC to quit the update and to disp...

Страница 152: ...work connection The right is the screen Wireless LAN is selected Wireless LAN settings 9 4 Wireless LAN Settings and Communication step 3 to 9 Cellular settings 9 5 Cellular Settings and Communication step 6 to 8 When selecting cellular communication Cellular 1 can be selected as an exception during Cloud OAF update Cellular 1 Built in SIM Cellular 2 SIM card inserted to the SIM card slot 5 Press ...

Страница 153: ...te The right screens are displayed during update 7 When the update is completed the instrument is restarted automatically 8 Display the version display mode screen and check if the functions on your instrument are changed The right screen is an example ...

Страница 154: ...orer Click the x button to exit the message PROCEDURE 1 Access TSshield web site from your PC Press More info for the instrument on the Dashboard to display Instrument page 2 Press Download in the General Information 3 Save the update file xx_xxxxxx oaf in the route folder of a USB flash drive If the destination to save downloaded files is not changed the downloaded file is saved in Download folde...

Страница 155: ...arts automatically 6 When the update is completed the instrument is restarted automatically 7 Display the version display mode screen and check if the functions on your instrument are changed 22 1 Cloud OAF Online Update step 8 ...

Страница 156: ...he instrument can perform RS232C communication D sub 9 pin at the same time as connecting to an external power source External power supply equipment Use an external battery BDC60A 61A with the charged standard battery BDC70 to fulfill the sufficient operating time and to maintain the balance of the instrument When using the Car cigarette lighter cable EDC115 leave the car engine running Use the 1...

Страница 157: ...dized screws it is possible to combine these prisms accessories etc according to your objectives Prism constant correction value 40 used alone Aperture 58 mm 360 Prism ATP1 360 Sliding Prism ATP1SII These 360 prisms reduce the possibility of lost prism during Auto Tracking measurement regardless of the direction of the prism 3D positioning accuracy standard deviation 3mm Horizontal acceptance angl...

Страница 158: ...f of the displacement by using the adjustment pin to rotate the plate level adjustment screw When the plate level adjustment screw is turned in the counterclockwise direction the bubble moves in the same direction 6 Rotate the top of the instrument and continue adjustments until the bubble remains centered for any position of the upper part If the bubble does not move to the center even when the a...

Страница 159: ...he side with one clasp is the upper surface Attach the belt hooks to the clasps on the carrying case shown in the figure on the right Warning Do not attach the belt hooks to the carrying case in the wrong direction The case or instrument could be dropped and cause injury Plumb bob optional accessory The plumb bob can be used to set up and center the instrument on days when there is little wind To ...

Страница 160: ...ve the compass from the slot The figure on the right is the standard handle Mounting method is the same for the RC handle The tubular compass is susceptible to the influence of nearby magnets or metal Such influence could cause it to fail to accurately indicate magnetic north Do not use magnetic north as indicated by this compass for base line surveying Telescope eyepiece lens EL8 optional accesso...

Страница 161: ...connecting to an external power source Remote Controller RC PR5A optional accessory This is the remote controller for Remote Control System which points the instrument iX in the direction of the prism with speed and precision Remote Control System Manual This system can be used in conjunction with the RC handle Cable Notes DOC210 Pin number and signal level RS232C compatible EDC211 Y cable D Sub c...

Страница 162: ... 0 0010 gon 0 015 mil iX 1005 505 5 0 0015 gon 0 025 mil Collimation compensation On Off selectable Measuring mode Horizontal angle Right Left selectable Vertical angle Zenith Horizontal Horizontal 90 selectable Tilt angle compensation Type Liquid 2 axis tilt sensor Correction unit 1 Range of compensation 6 Automatic compensator ON V H V OFF selectable Tilt offset Can be changed Distance measureme...

Страница 163: ...ement distance Unit mm Under normal atmospheric conditions 1 7 9 ISO 17123 4 2001 Using prism or using 360 Prism ATP1 ATP1S 3 iX 1000 series Fine measurement 1 0 2 ppm X D mm Rapid measurement 5 2 ppm X D mm iX 500 series Fine measurement 2 0 2 ppm X D mm Rapid measurement 5 2 ppm X D mm Using reflective sheet target 4 Fine measurement 2 2 ppm X D mm Rapid measurement 5 2 ppm X D mm Reflectorless ...

Страница 164: ...y depending on the model the country or the area where the instrument is purchased Auto Pointing Auto Tracking Auto Tracking function is for Auto Tracking model only Measuring method Pulse laser transmitter and image detector with co axial optics Signal source emitted beam Infrared laser diode 980 nm Class 1 IEC60825 1 Ed 3 0 2014 FDA CDRH 21 CFR Part 1040 10 and 1040 11 Complies with FDA performa...

Страница 165: ...n speed 17 iX 1000 series 150 sec at 20 C iX 500 series 85 sec at 20 C Fine motion Jogs 17 Specifications may vary depending on the model the country or the area where the instrument is purchased Guide Light Light source LED red 626 nm green 524 nm Visible distance range 1 3 to 150 m 18 Visible angle range Right and Left Upward and Downward 4 7 m 100 m Brightness level is less than 80 000 lx 19 wh...

Страница 166: ... RC PR5A 24 25 23 Bluetooth function may not be built in depending on telecommunications regulations of the country or the area where the instrument is purchased Contact your local dealer for the details 24 No obstacles few vehicles or sources of radio emissions interference in the near vicinity of the instrument no rain 25 Usage range could be shorter depending on specifications of Bluetooth devi...

Страница 167: ...harging temperature range 0 to 40 C Storage temperature range 20 to 65 C Size 94 W X 102 D X 36 H mm Weight about 170g 30 Figures will change depending on the operating environment including temperatures and observation conditions 31 Figures when using the instrument with both an external battery and a standard battery mounted General Operating system Windows Embedded Compact 7 Display 4 3 inch Tr...

Страница 168: ...r less Brightness control 5 levels Auto power off Provided power cut off after 5 minutes Calendar clock function Yes Laser pointer function ON OFF selectable Operating temperature range 20 to 50 C 4 to 122 F Storage temperature range 30 to 60 C 22 to 140 F no condensation Dust and water resistance IP65 IEC 60529 2001 Instrument height 192 5 mm from tribrach mounting surface Size with handle Displa...

Страница 169: ...d hexagonal points on its rubber flanges are aligned with the sighting direction of the instrument see the diagram below When using the ATP1SII the 360 Prism should be set up so that a pair of diametrically opposed marks on top of the prism are aligned with the sighting direction of the instrument 27 1 High Accuracy with the 360 Prism Hexagonal points Prism sighting direction ...

Страница 170: ... 4 Collimation PROCEDURE 1 Select Instrument in Inst config Set V manual vertical circle indexing method to Yes 19 7 Instrument Conditions Instrument V manual 0 set is displayed 2 Carefully level the instrument 3 Accurately sight a clear target with a distance of 30 m or more in the horizontal direction with the telescope in Face 1 Press OK The vertical angle V2 is displayed under Take F2 4 Turn t...

Страница 171: ...zontal and vertical distances Horizontal distance D AC α Vertical distance Z BC α D L cosα 2θ γ sinα Z L sinα θ γ cosα θ L cosα 2R Earth curvature correcting item g K Lcosα 2R Atmospheric refraction correcting item K 0 142 or 0 2 Coefficient of refraction Ref index R 6371km Radius of earth a Altitude angle L Slope distance Changing Coefficient of refraction value K Ref index 19 1 Observation Condi...

Страница 172: ... likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Means of conformity This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesire...

Страница 173: ... to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of this device This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment and meets the RSS 102 of the IC radio frequency RF Exposure Guidelines This equipment has very low levels ...

Страница 174: ...t may not be treated as household waste By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about the take back and recycling of this product please contact your supplier where you purchased the produc...

Страница 175: ...ce resolution 111 DNS server and WINS server 44 E EDM ALC 111 Eliminating parallax 59 G Guide light 10 H Hdist 110 Horizontal angle settings 74 80 Horizontal jog 10 I Inch Fraction of an inch 120 Instrument height mark 9 K Key backlight 117 L Laser pointer function 9 Laser pointer off 119 Lost Prism 57 P Power off 118 Power off Remote 118 Power saving mode 117 Precaution when performing resection ...

Страница 176: ...T Terminate 38 Tracking Meas 55 Tracking reso Tracking resolution 111 Trigger key 10 TURN 55 Turning operation 58 V V mode vertical angle display method 109 Vertical Jog 10 ...

Страница 177: ...http www topcon co jp GLOBAL GATEWAY http global topcon com Please see the attached address list or the following website for contact addresses 2016 TOPCON CORPORATION ALL RIGHTS RESERVED ...

Отзывы: