91
15. SETTING-OUT MEASUREMENT
Record all the setting-out points (includes setting-
out points you will measure from now).
Press
[ADD]
to record new data.
• Switch the Operating icons and press
[DEL]
to
delete the selected setting out point.
• Press
[DELALL]
to delete all setting out points.
4. Select a setting-out point in the first screen of step
3 and press
[OK]
to display <Set out Coords>.
5. Position the target on the line of sight and press
[H.TURN]
to automatically rotate the instrument
until the angle of the setting out point reads 0
°
.
Press
[MEAS]
to begin distance measurement.
The distance and direction to move the target until
the setting out point is located is displayed on the
instrument. The sighting point measurement
results (currently installed position of the target)
are displayed.
• Tap the screen title to display popup and "NEZ"
display can be selected.