113
19. CHANGING THE SETTINGS
PROCEDURE Editing target information
1. Select a target to edit in <Reflector> and press
[EDIT]
. Select/input relevant information for the
target.
Items set and options
(1) Reflector type
Prism/Sheet/N-Prism/360° Prism
(2) Prism Const.correction value
-99 to 99 mm
(3) Aperture
1 to 999 mm
• When 0.1mm is selected in "Dist.reso", "Prism
constant value" can be input to the first decimal
place.
"19.1 Observation Conditions - Angle/Tilt"
•
[DEL]
: Deletes the selected target.
2. Press
[OK]
to confirm the settings.
PROCEDURE Adding a target
1. Press
[ADD]
in <Reflector> to display the list of
candidate targets.
2. Select a frequently-used target from the list
referring prism const.correction value and
aperture.
• Up to a maximum of 6 targets can be registered.
• When selecting "N-Prism", prism constant
correction value and aperture are not set.
3. Press
[OK]
to confirm the settings.