13. SETTING INSTRUMENT STATION
78
13.2.4 Height Resection Measurement
Only Z (height) of an instrument station is determined by the measurement.
• Known points must be measured by distance measurement only.
• Between 1 and 10 known points can be measured.
PROCEDURE
1. Select "Occ.orien." from the
coordinate measurement menu.
2. Press
[RESEC]
in the "Occ.orien."
3. Select “Elevation”.
• The tilt screen is displayed if the
instrument is out of level.
Level the instrument.
"7.2 Levelling"
4. Sight the first known point and
press
[MEAS]
to begin
measurement. Press
[STOP]
.
The measurement results are
displayed on the screen.
5. Press
[YES]
to use the
measurement results of the first
known point.
6. Input the known point. After
setting the elevation for the first
known point, press
[NEXT]
to
move to the second point.
Resection.
NEZ
Setting
Elevation
Resection 1st PT
SD
ZA
HA-R
80
140
42
49
15
15
MEAS
1 s t P T
Z p :
H R
0 . 1 0 0 m
1 1 . 8 9 1
REC
LOAD
NEXT
CALC