299
37. SPECIFICATIONS
Laser plummet (option):
Signal source:
Red laser diode 635 ±10nm (Class 2 IEC60825-
1 Ed. 2.0:2007/ FDA CDRH 21CFR Part
1040.10 and 1040.11 (Complies with FDA
performance standards for laser products except
for deviations pursuant to Laser Notice No.50,
dated June 24, 2007.))
Beam accuracy:
1mm or less (when tripod head height is 1.3m).
Spot diameter:
ø3mm or less
Brightness control:
5 levels
Auto power-off
Provided (power cut off after 5 minutes)
Operating temperature (no condensation)
Standard models:
-20 to 60 °C (-4 to 140 °F)
*13
Low temperature models:-35 to 50 °C (-31 to 122 °F)
*4
Storage temperature range (no condensation):
Standard models:
-30 to 70 °C (-22 to 158 °F)
Low temperature models:-35 to 70 °C (-31 to 158 °F)
Dust and water resistance:
IP66 (IEC 60529: 2001)
Instrument height:
192.5 mm from tribrach mounting surface
236mm +5/-3mm from tribrach bottom
Size (with handle):
CX-101/102/103/105:
191 (W) X 181 (D) X 348 (H) mm
CX-107:
191 (W) X 174 (D) X 348 (H) mm
Weight (with handle and battery):
5.6kg (12.3 lb)
*13
:
No direct sunlight for using high temparatures of 50 to 60 °C (122 to 140
°F) .
Содержание CX-101
Страница 2: ... This is the mark of the Japan Surveying Instruments Manufacturers Association Li ion S Li ion ...
Страница 10: ...viii ...
Страница 318: ...39 REGULATIONS 308 ...
Страница 320: ......
Страница 321: ......