33. CHANGING THE SETTINGS
256
• Atmospheric correction factor is calculated and set using the entered values of
the temperature and air pressure. Atmospheric correction factor can also be
entered directly.
• "Illum. hold" and "Guide light" are displayed only for the CX Series.
Items set, options, and input range (*: Factory setting)
• The screen will be displayed only when "Illum. hold " is set to "Guide" and the
cursor is on "Guide".
Item set and option (*: Factory setting)
Mode (Distance measurement
Mode)
Fine “r”*, Fine AVG (Setting: 1 to 9 times),
Fine “s”, Rapid "r", Rapid “s”, Tracking
Reflector
Prism*, Sheet, N-prism (reflectorless)
PC (Prism constant)
-99 to 99 mm ("Prism" is selected: 0*,
"Sheet" is selected: 0*)
Illum. hold
Laser (laser sight)*, Guide (Guide light)
Temp. (Temperature)
-35 to 60°C (15*)
Air pressure
500 to 1400hPa (1013*)/
375 to 1050mmHg (760*)
ppm (Atmospheric correction
factor)
-499 to 499 (0*)
The Guide light (Brightness
level of the guide light)
1 to 3 (3*)
EDM
Mode
Reflector
PC
Illum.hold
Guide light
: Fine r
: Prism
: 0
:
Guide
: 3