141
21. MISSING LINE MEASUREMENT
• When
[MOVE]
is pressed, the
last target measured becomes
the new starting position to
perform missing line
measurement of the next target.
5. Press
{ESC}
to end missing line
measurement.
PROCEDURE Calculating from input coordinates
1. In the third page of OBS mode
screen, press
[MLM]
, then select
"MLM".
2. Press
[COORD]
on the second
page.
3. Input coordinates for the 1st target
and press
[OK]
.
• When you wish to read in and set
coordinate data from memory,
press
[LOAD]
.
Station Data and Azimuth
Angle PROCEDURE
Reading in Registered
Coordinate Data"
4. Select "PT2" and press
{ENT}
to
proceed to 2nd target input.
MLM
Occ.Orien.
MLM
MLM
Set PT1
SD
ZA
HA-R
80
140
42
42
15
15
P2
COORD
S/%
T
g
t.h
N
E
20.000
30.000
40.000
Z
OK
PT1
REC
LOAD
Input Coord
PT1
PT2